Part V - Quality Assurance Project Plan 133-135 Greenwich Street/21-23 Thames Street Airtek Project 05-0701 - November 4, 2005

Depending on the analysis, analytical results will be reported within 24 hours or three (3) to five (5) business days of receipt of samples by the laboratory. Non-detect results must be reported down to the quantitation limit and qualified with a U. All information related to analysis will be documented in controlled laboratory logbooks, instrument printouts, or other approved forms. All entries that are not generated by an automated data system will be made neatly and legibly in permanent, waterproof ink. Information will not be erased or obliterated. Corrections will be made by drawing a single line through the error and entering the correct information adjacent to the cross-out. All changes will be initialed, dated, and, if appropriate, accompanied by a brief explanation. Unused pages or portions of pages will be crossed out to prevent future data entry. Laboratory records will be reviewed by the Laboratory Section Leaders on a regular basis, and by the Laboratory QA Manager periodically, to verify adherence to documentation requirements.

14.4.2.2 Electronic Deliverables

Laboratory data will be received as hard copy and electronic data deliverables (EDD). EDDs associated with fixed laboratory analyses will be in Excel format. A copy of the required EDD format is provided in Attachment E. A spreadsheet will be generated using the EDDs to provide results of the target parameters compared to the Target Air Quality Levels, 3x the Target Air Quality Levels, and the USEPA Site- Specific Trigger Levels. The laboratory will calculate all results using sample volumes provided by AIRTEK. A rolling average will be generated after the first week of sampling. Results will subsequently be compared and rolled into this average. The EDDs associated with dioxin/furan results will include speciated results for each dioxin/furan congener, the TEEs used, and the TEQ. The EDDs associated with PAH results will include speciated results for each target PAH, the BAP-factors used, and the BAP-equivalent concentration. The EDDs associated with PCB results will include the results for individual Aroclors as well as the result for total PCBs.

14.5 Data Handling and Management

14.5.1 Data Entry and Verification

All data entry performed by AIRTEK or its contractors will be proofed 100% for accuracy. Verification will be carried out either by proofing a printout against the original data or by duplicate entry and comparison of the two data sets to detect discrepancies.

14.5.2 Data Transformation and Reduction

14.5.2.1 Dioxins/Furans Transformation and Reduction

The laboratory will be responsible for calculating the toxicity equivalent quotient

111

CITY_21MC100_0 07120829

NYC-WTC_000444606

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000444606Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000441133

Plan for Environmental Community Air Monitoring at Greenwich/Thames sites, Nov 2005.

Similar indexed content

NYC-WTC_000441316

Plan for Environmental Community Air Monitoring at Greenwich Street and Thames Street sites, Nov 2005.

Similar indexed content

NYC-WTC_000453085

Plan for Greenwich Street and Thames Street monitoring within WTC-related cleanup.

Similar indexed content

NYC-WTC_000446622

Part V plan for Environmental Community Air Monitoring at Greenwich/Thames sites.

Similar indexed content

Compare copies and versions →