Quality Assurance Plan, ambient air monitoring, Liberty Plaza

Machine-extracted title · confidence 66%

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 2005.

NYC-WTC_000444248–000444379
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

z ■< Z ■<

o o io Ambient Air Monitoring Program Quality Assurance Project Plan 130 Liberty Street - NY, NY Section No. 8 Revision No.: 0 Date: September 1,2005 co

I Lower Manliattan Development Corporation Page 52 of 124 “0 o c o CT o o' "0 Ca5 o O O 9L Table 8-8. Measurement Performance Criteria Table - Asbestos by I EM/SEM " O o QC Sample or Activity Frequency Measurement Performance Criteria Corrective Action DQI o c Field Duplicates 1/week *RPD < 40 when positive results for both Assess laboratory precision, and/or Precision-Overall 3 o samples are > 5x QL qualify data. 3 *No situation where one result is detected at > 5x QL and other result is not detected Standaid Reference Materials 1/year Percent recoveries 80-110% Recalibrate, reanalyze, and/or Accnracy/Bias qualify data. Intra-analyst QC 1/50 samples < 5 structures: + 1 structure Recalibrate, reanalyze, and/or Precision 5-20 structures: + 2 structures qualify data. > 20 structures: -I- 3 structures Inter-analyst QC 1/25 samples < 5 structures: + 1 structure Recalibrate, reanalyze, and/or Precision 5-20 structures: + 2 structures qualify data. > 20 structures: + 3 structures Method Blanks 1/batch < 53 structures/mm^ in blank Locate source of contamination and Accuracy/Bias - <18 sti uclui es/mnr in cumulative average coiTect before analysis can proceed. Contamination Field/Trip Blanks l/day<^’ Arithmetic mean of 3 field blanks must be Retest, reanalyze, and/or qualify Accuracy/Bias - < 70 S/mnr___________________________ data.___________________________ Contamination Data Completeness Check NA Field 80%, Laboratory 95% NA Data Completeness Refer to Section 11.1.2.3 for procedures to be used for measuring structures and fibers. *^^Only analyzed if asbestos is detected in the associated samples. Reanalyze: refers to reanalysis of same sample.

o H K I to

S o o o I o

L2005-346 Rev. 1

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000444300Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000447031

QA plan document for ambient air monitoring program for Liberty Street deconstruction.

Similar indexed content

NYC-WTC_000449908

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, Sept 7, 2005.

Similar indexed content

NYC-WTC_000443239

QA plan for ambient air monitoring at 130 Liberty Street deconstruction project, LMDC.

Similar indexed content

NYC-WTC_000447891

QA plan for ambient air monitoring at 130 Liberty Street, Sept 7, 2005.

Similar indexed content

Compare copies and versions →