NYC 9/11 Public Portal Document
Part V - Quality Assurance Project Plan
133-135 Greenwich Slreet/21-23 Thames Street
Airtek Project 05-0701 - November 4, 2005
parameters only. Laboratory duplicates are typically performed at a frequency of one per
twenty samples.
11.2.2.6 Internal Standards Internal standards are used to assess the analytical accuracy,
precision, and stability. Internal standards are typically only used for organic analyses
and ICP/MS analyses. Internal standards are spiked into all samples and are considered a
sample-specific QC measure.
11.2.2.7 Standard Reference Materials Standard reference materials (SRMs) are used to
evaluate laboratory preparation and analysis bias for specific compounds in a reference
matrix. SRMs will be used for the asbestos analysis.
11.2.2.8 Matrix Spike Samples The matrix spike samples are used to determine laboratory
preparation and analysis bias for specific compounds in specific matrices (i.e., sample
specific QC). Matrix spikes are typically performed at a frequency of one per twenty
investigative samples per analytical parameters with the exception of the RCRA
characteristics.
12.0 SAMPLE HANDLING AND CUSTODY REQUIREMENTS
Summaries of sample media, required sample volumes, preservation, and holding
time requirements for all samples are presented in Table 12-1 and Table 12-2. With the
exception of samples that are completed on Sundays, samples will be delivered to
the laboratories via Federal Express immediately after collection on ice (where required)
with coolers under custody seal or via courier service. Samples completed on Sundays
will be shipped with Monday’s shipment.
12.1 Sample Custody
Sample custody is addressed in two parts: field sample collection and laboratory
analysis. A sample is considered to be under a person’s custody if • the item is in the
actu al possession of a person; • the item is in the view of the person after being in actu al
possession of the person; • the item was in the actual physical possession of the person
but is locked up to prevent tampering; and, • the item is in a designated and identified
secure area.
12.1.1 Field Sample Custody
Sample handling is an important part of the field investigation program since samples
that are incorrectly handled can affect the quality of data. Sample handling begins at the
collection of the samples and continues until the sample has been analyzed. An over
riding consideration essential for the validation of environmental measurement data is the
necessity to demonstrate that samples have been obtained from the locations stated and
that they have reached the laboratory without alteration. Evidence of sample tracking
from collection to shipment, laboratory receipt, and laboratory custody (until proper
74
CITY_21MC100_0 07120926
NYC-WTC_000443815
OCR can misread numbers and units. Confirm readings against the page image before using them.