133-135 Greenwich Slreet/21-23 Thames Street
Airtek Project 05-0701 - November 4, 2005
each parameter. In general, the proposed analytical methodologies will be able to achieve
the PQOs. That is, the analytical methodologies are generally capable of detecting the
target analytes well below the applicable action limit. These methods provide data of
known quality and can be used for the objectives of this program. However, in order to
ensure that the analytical methodologies are capable of achieving the data quality
objectives, measurement performance criteria have been set for the analytical
measurements in terms of accuracy, precision, representativeness, completeness,
sensitivity, selectivity, and comparability.
Tabic 8-la. Comparison of Laboratory Quantitation Limits with Project Action Levels
Parameter Estimated Laboratory Quantitation Project Action Levels
Volume to Limits (QLs)
Target USEPA
be
Air Site-
Collected
Quality Specific
Level Trigger
Levels
Metals
Antimony 1440 m3 2.4 pg 1.67 X 10-3 5 pg nV 14 pg m'
pg nV
Barium 1440 m3 120 pg 0.083 5 pg nV 5 pg m'
pg/m^
Beryllium 1440 m3 1.2 pg 8.33 X 10-4 .02 pg nV 0.2 pg m'
pg/m^
Cadmium 1440 m3 1.2 pg 8.33 X 10-4 .04 pg nV 2 pg m'
pg/m’
Chromium^ 1440 m3 12 pg 8.33x 10-3 0.6 pg nV 0.6 pg m'
pg/m3
Copper 1440 m3 6 pg 4.17 x 10-3 10 pg/m’ 100 pg nV
pg/m^
Lead 1440 m3 1.2 pg 8.33 X 10-4 1.5 pg nV 5 pg m'
pg/m3
Manganese 1440 m3 6 pg 4.17x10-3 0.5 pg nV 0.5 pg/m’
lOpg/m^
Mercury .0576 m3 0.015 pg 0.026 0.3 pg nV 3 pg m'
pg/m^
Nickel 1440 m3 6 pg 4.17x10-3 0.2 pg nV 28 pg m'
pg/m^
Zinc 1440 m3 24 pg 0.0167 16 pg/m’ 160 pg nV
pg/m3
Particles and Dust
Asbestos 2.88 m3 0.002 0.0009 70 S/mm2
s/cm3 f/cm3 (TEM
(PCME AHERA
fibers) structures)
32
CITY_21MC100_007120884
NYC-WTC_000443773
OCR can misread numbers and units. Confirm readings against the page image before using them.