NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 3 pages

Panel discussion notes on sampling phases, DEP

Machine-extracted title · confidence 41%

Interim panel recommendations for phased sampling and WTC signature assessment.

NYC-WTC_000443376–000443378
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Sampling Collection, Analytical Methods and Evaluation Criteria

Please refer to the COPC document prepared by EPA. The sampling collection and analytical methods should remain consistent with previous sampling strategies. Samples for asbestos, lead, polyaromatic hydrocarbons (PAHs), dioxin, fibrous glass, and crystalline silica should be collected by the sampling and analytical methods specified in Table 2. In addition to the COPC, Panel may recommend additional chemicals or compounds that need to be analyzed. The analytical results should be evaluated based pre-determined criteria. Levels used in clearance sampling at WTC sites are presented in Table 2. Levels found to be above these levels shall require further evaluation and assessment, including an examination of potential sources other than the collapse of the WTC.

Table 2: Sampling and Analytical Methods Parameter Description Sampling Analytical Evaluation Criteria Methodology Method^

Lead Wipe HUD EPA Method SW- 25 ptg/fF samples Appendix 846-601OB 13.1 PAHs Wipe ASTMD6661- ASTM-6661-01 samples 01 EPA SW-846- 8270C 150 pg /m^ The detection limit for PAHs shall be no greater than 1 *g/m2 Dioxin Wipe ASTM 6661- ASTM 6661-01 samples 01 EPA Method SW- 2 ng/m ’ 846-8290^ Fibrous Wipe Glass samples Crystalline Wipe Silica samples Asbestos Bulk Title 15, 1% samples Chapter 1 of the Rules of the City of New York (RCNY) and AHERA ' The environmental laboratory- must be certified by the New York State Department of Health. Certification for all the analytes specified herein must have been maintained for at least six (6) consecutive proficiency testing rounds. The laboratory must possess a gas chromatograph equipped with a capillary column and high-resolution mass spectrometer for analyzing dioxin and inductively coupled plasma for total metals.

CITY_21MC100_003235796

NYC-WTC_000443377

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000443377Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →