Environmental Protection Agency Pt. 763, Subpt. E. App. C out; proper working techniques for mini­ guide specifications for a particular building; mizing fiber release; entry and exit proce­ worker and building occupant health/medical dures for the work area; use of wet methods; considerations; replacement of ACM with proper techniques for initial cleaning; use of non-asbestos substitutes. negative-pressure exhaust ventilation equip­ (m) Preparing abatement drawings. Signifi­ ment; use of HEPA vacuums; proper clean-up cance and need for drawings, use of as-built and disposal of asbestos; work practices as drawings as base drawings; use of inspection they apply to encapsulation, enclosure, and photographs and on-site reports; methods of repair; use of glove bags and a demonstration preparing abatement drawings; diagramming of glove bag use. containment barriers; relationship of draw­ (e) Field trip. A visit to an abatement site ings to design specifications; particular or other suitable building site, including on­ problems related to abatement drawings. site discussions of abatement design and (n) Contraet preparation and administration. building walk-through inspection. Include (o) Legal/liabilities/defenses. Insurance con­ discussion of rationale for the concept of siderations; bonding; hold-harmless clauses; functional spaces during the walk-through. use of abatement contractor’s liability insur­ (f) Employee personal protective equipment. ance; claims made versus occurrence poli­ Classes and characteristics of respirator cies. types; limitations of respirators; proper se­ (p) Replacement. Replacement of asbestos lection, inspection; donning, use, mainte­ with asbestos-free substitutes. nance, and storage procedures for res­ (q) Role of other consultants. Development pirators; methods for field testing of the of technical specification sections by indus­ facepiece-to-face seal (positive and negative- trial hygienists or engineers; the multi-dis­ pressure fit checks); qualitative and quan­ ciplinary team approach to abatement de­ titative fit testing procedures; variability sign. between field and laboratory protection fac­ (r) Occupied buildings. Special design proce­ tors that alter respiratory fit (e.g., facial dures required in occupied buildings; edu­ hair); the components of a proper respiratory cation of occupants; extra monitoring rec­ protection program; selection and use of per­ ommendations; staging of work to minimize sonal protective clothing; use, storage, and occupant exposure; scheduling of renovation handling of non-disposable clothing. to minimize exposure. (g) Additional safety hazards. Hazards en­ (s) Relevant Federal, State, and local regu­ countered during abatement activities and latory requirements, procedures and standards, how to deal with them, including electrical including, but not limited to: hazards, heat stress, air contaminants other (i) Requirements of TSCA Title II. than asbestos, fire, and explosion hazards. (ii) National Emission Standards for Haz­ (h) Fiber aerodynamics and control. Aero­ ardous Air Pollutants, (40 CFR part 61) sub­ dynamic characteristics of asbestos fibers; parts A (General Provisions) and M (National importance of proper containment barriers; Emission Standard for Asbestos). settling time for asbestos fibers; wet meth­ (iii) OSHA Respirator Standard found at 29 ods in abatement; aggressive air monitoring CER 1910.134. following abatement; aggressive air move­ (iv) EPA Worker Protection Rule found at ment and negative-pressure exhaust ventila­ 40 CFR part 763, subpart G. tion as a clean-up method. (v) OSHA Asbestos Construction Standard (i) Designing abatement solutions. Discus­ found at 29 CFR 1926.58. sions of removal, enclosure, and encapsula­ (vi) OSHA Hazard Communication Stand­ tion methods; asbestos waste disposal. ard found at 29 CFR 1926.59. Ci) Final clearance process. Discussion of the (t) Course review. A review of key aspects of need for a written sampling rationale for ag­ the training course. gressive final air clearance; requirements of 6. Project Monitor a complete visual inspection; and the rela­ tionship of the visual inspection to final air EPA recommends that States adopt train­ clearance. ing and accreditation requirements for per­ EPA recommends the use of TEM for anal­ sons seeking to perform work as project ysis of final air clearance samples. These monitors. Project monitors observe abate­ samples should be analyzed by laboratories ment activities performed by contractors accredited under the NIST NVLAP. and generally serve as a building owner’s (k) Budgeting/cost estimating. Development representative to ensure that abatement of cost estimates; present costs of abatement work is completed according to specification versus future operation and maintenance and in compliance with all relevant statutes costs; setting priorities for abatement jobs and regulations. They may also perform the to reduce costs. vital role of air monitoring for purposes of (1) Writing abatement specifications. Prepara­ determining final clearance. EPA rec­ tion of and need for a written project design; ommends that a State seeking to accredit in­ means and methods specifications versus dividuals as project monitors consider adopt­ performance specifications; design of abate­ ing a minimum 5—day training course cov­ ment in occupied buildings; modification of ering the topics outlined below. The course

715

CITY_21MC100_003219302

NYC-WTC_000442773

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000442773Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →