Part V - Quality Assurance Project Plan 133-135 Greenwich Street/21-23 Thames Street Airtek Project 05-0701 - November 9, 2005

Min Container Sample Holding Ana/yte Method volume Type Freservatio Time (mL) n Acidity EPA 305.1/SM 2310 B 1000 P,G Cool, 4 °C 14 days Alkalinity EPA310.1/SM 2320 B 1000 P,G Cool, 4 °C 14 days Chlorinated EPA 608/ SW 8080 1000 GA Cool, 4 °C 7/14 Pesticides and days PCB’s Corrosivity SW846 Method 9045D or 9040C 500 P, G, Cool, 4 °C immed Plame AA Metals SW 7000/ 500 P HNO3 pH<2 6 mo GFAA Metals SW 7000/________________ 500 P HNO3 pH<2 6 mo Hexavalent SW7186 500 P,G Cool, 4 °C 24 hr Chromium ICP Metals SW 846 Method 6010B or 6020 500 P HNO3 pH<2 6 mo Ignitability ASTM D-93-79 or D-93-80 100 g G Cool, 4 °C 28 days (Flashpoint) or D-3278-78.

Mercury EPA 245.1/SM3112 B/ 500 P HNO3 pH<2 6 mo SW846 Method 7470A PAH SW 8100____________ 1000 GA Cool, 4 °C 7/40days PAH SW 8310 1000 GA Cool, 4 °C 7/30 days PCB EPA 608/ SW 8082 1000 GA Cool, 4 °C 7/40 days pH EPA 150.1/SW 9040 B/ 500 P,G Cool, 4 °C immed Reactive Cyanide SW 9012 A, 7.3_______ 1000 P,G Cool, 4 °C 14 days Reactive Sulfide SW 9030 B/9034 500 P,G zinc acetate, 7 days NaOH pH>9 TCEP Semivolatile EPA 625/ SW 3510 C/ 8270C 1000 GA Cool, 4 °C 7/40 Organics days TCEP VolatUe EPASW846-1311/8260B 1000 GA Cool, 4 °C 7/40 Organics days TCEP Pesticide SW846 Method 8081A 1000 GA Cool, 4 °C 7/40 days TCEP Herbicide SW846 Method 8151A 1000 GA Cool, 4 °C A40 days P = plastic, HDPE G = glass GA= amber glass VOA = 40 mL vial

Preservation should be performed at time of sample collection. Sample bottles with or without preservative may be obtained by contacting the laboratory. Indication of preservative would be helpful either on the label or a sample chain of custody (also available from the lahoraloiy). The holding times listed in the table are the maximum allowable time a sample can be held before analysis and still be in compliance with the EPA regulations. Sample collection date and time are needed to ensure that holding times are met properly.

10.3 Field Quality Control

This section of the QAPP identifies the QC procedures, checks, samples, and their respective acceptance limits, that will be used to monitor the quality of various aspects of the sampling event. Their required analysis frequency, acceptance limits and corrective

68

CONFIDENTIAL, CITY_21MC100_007849844 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000442477

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000442477Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000451808

Plan for Greenwich Street and Thames Street air monitoring project, Nov 9, 2005.

Similar indexed content

NYC-WTC_000441316

Plan for Environmental Community Air Monitoring at Greenwich Street and Thames Street sites, Nov 2005.

Similar indexed content

NYC-WTC_000420513

Plan for environmental air monitoring around The Greenwich Street and Thames Street sites.

Similar indexed content

NYC-WTC_000444496

Plan documents for environmental community air monitoring at Greenwich/Thames street sites, Nov 2005.

Similar indexed content

Compare copies and versions →