NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 134 pages

Greenwich/Thames plan: Environmental monitoring

Machine-extracted title · confidence 32%

Plan for Environmental Community Air Monitoring at Greenwich Street and Thames Street sites.

NYC-WTC_000442410–000442543
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Part V - Quality Assurance Project Plan 133-135 Greenwich Street/21-23 Thames Street Airtek Project 05-0701 - November 9, 2005

Field/Trip 1/day No target Reclean, Accuracy/Bias- Blanks compounds > reanalyze, Contamination QL and/or qualify PUF Media 1/batch cleaned No target Reclean, Accuracy/Bias- Cleaning compounds > reanalyze, Contamination Verification QL and/or qualify Check Recovery Every sample, Signal: noise Reanalyze Accuracy/Bias Standards blank, QC ratio must be > and/or qualify 10:1 data. Data NA Field 80%; NA Data Completeness Laboratory Completeness Check 95% ° Tricludes the following compounds: ” CU-2,3,7,8-TCDD:1.6ng «Ci2-l,2,3,4,7-PeCDD;4ng ‘’Ci2-1.2.3.4.6-PeCDF:4ng '’C12-1,2,3,4,6,9-HxCUFL4ng ‘’Ci2-l,2,3,4,6,8,9-HpCDF:4ng Field duplicates may not be consistently collected at a frequency of 1/week during Abatement and Demolition Phases as the location selected for analysis will he dictated by PMw measurements. 3 Will be collected at a frequency of 1/day; during Abatement and Demolition Phases only 1 field/trip blank per week will be analyzed. Reanalyze: refers to reanalysis of the same extract.

Tab/e 8-6, Measurement Performance Criteria Tab/e-Mercurv bi^ CVAFS QC Sample or Frequency Measurement Corrective DQI Activity Performance Action Criteria Field 1/every other week *RPD < 40 Assess Precision- Duplicates^ when positive laboratory Overall results for both precision; and samples are > /or qualify 5x QL data. *No situation where one result is detected at > 5x QL and other result is not detected Laboratory 1/prep batch Percent Determine Accuracy/Bias Control recoveries 80- cause of Sample 120% problem, reanalyze, and/or qualify data.

46

CONFIDENTIAL, CITY_21MC100_007849822 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000442455

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000442455Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000451808

Plan for Greenwich Street and Thames Street air monitoring project, Nov 9, 2005.

Similar indexed content

NYC-WTC_000441316

Plan for Environmental Community Air Monitoring at Greenwich Street and Thames Street sites, Nov 2005.

Similar indexed content

NYC-WTC_000420513

Plan for environmental air monitoring around The Greenwich Street and Thames Street sites.

Similar indexed content

NYC-WTC_000444496

Plan documents for environmental community air monitoring at Greenwich/Thames street sites, Nov 2005.

Similar indexed content

Compare copies and versions →