Part V - Quality Assurance Project Plan 133-135 Greenwich Street/21-23 Thames Street Airtek Project 05-0701 - November 9, 2005

monitors as a QA check. The TEOM sampler will rotate on a bi-weekly basis through all real-time PMio monitor locations for the duration of the monitoring program.

10.2.9.1 PMio-Reference Method via TEOM 1400a

Rupprecht & Patshinck TEOM Series 1400a monitor will measure the ambient particulate mass concentration of PM-10 in real time. The instrument has the USEPA equivalency designation for PM-10 as EQPM-1090-079. Measured values and identification of flags indicating any anomalies are recovered by the operator by downloading a sample summary to a laptop or handheld computer.

10.2.9.2 PMw- Continuous Monitoring ofPMwvia Met One E-BAM Samplers

The monitors selected to continuously measure PMio are beta-attenuation monitors manufactured by Met One Instruments, Inc. (Met One). The E-BAM monitors will be equipped with particle size selective inlets. The design of the inlets is such that particles larger than the desired size range will be removed from the air flow at the prescribed air flow rate. The units will be equipped with an inlet head to separate PMio. Sampling flow rate is critical to maintain the proper particle size cut points of the inlets. Plow rates are maintained at 16.7 liters per minute in the E-BAM monitors using an integral flow meter, pressure sensor, and ambient temperature sensor on board each monitor.

10.2.10 PM2.5

PM2.5 will be determined by two separate methods. At each location, PM2.5 will be determined by a non-reference method utilizing Met One’s E-BAM Mass Monitor, which is a real-time monitor. A Rupprecht & Patshinck TEOM Series 1400a monitor measuring the ambient particulate mass concentration of PM-2,5 in real time will be operated at one location each day. The TEOM sampler will be collocated along side the E-BAM PM2,5 monitors as a QA check. The TEOM sampler will rotate on a bi-weekly basis through all real-time PMio monitor locations for the duration of the monitoring program.

10.2.10.1 PM2.5 - Reference Method via Rupprecht & Patshinck TEOM Series 1400a Monitor

Rupprecht & Patshinck TEOM Series 1400a monitor with a sharp-cut {M2.5 cyclone will measure the ambient particulate mass concentration of PM-2.5 in real time. Measured values and identification of flags indicating any anomalies are recovered by the operator by downloading a sample summary to a laptop or handheld computer.

10.2.10.2 Continuous Monitoring 0/PM2.5 via Met One E-BAM Samplers

The monitors selected to continuously measure PM2.5 are beta-attenuation monitors manufactured by Met One Instruments, Inc. (Met One). The E-BAM monitors will be equipped with particle size selective inlets. The design of the inlets is such that particles

64

CITY_21MC100_0 03240576

NYC-WTC_000441379

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000441379Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000444496

Plan documents for environmental community air monitoring at Greenwich/Thames street sites, Nov 2005.

Similar indexed content

NYC-WTC_000441133

Plan for Environmental Community Air Monitoring at Greenwich/Thames sites, Nov 2005.

Similar indexed content

NYC-WTC_000453085

Plan for Greenwich Street and Thames Street monitoring within WTC-related cleanup.

Similar indexed content

NYC-WTC_000446622

Part V plan for Environmental Community Air Monitoring at Greenwich/Thames sites.

Similar indexed content

Compare copies and versions →