NYC-WTC_000437816
Plan document for Environmental Community Air Monitoring at Greenwich and Thames sites, Nov 4, 2005.
95 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗Plan for Environmental Community Air Monitoring at Greenwich/Thames sites, Nov 2005.
NYC-WTC_000441133–000441266OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Part V - Quality Assurance Project Plan 133-135 Greenwich Street/21-23 Thames Street Airtek Project 05-0701 - November 4, 2005
fastened to a location (i.e., on a tripod) near the individual’s breathing zone, the top cover of the filter cassette cowl extension (“open face”) will be removed and positioned “face down” in the sampler. The joint between the extender and monitor body will be wrapped with tape to hold the cassette securely in place and to provide a surface to identify the cassette. By inserting a pin through the hole near the display screen, the elapsed time indicator is reset prior to sampling. At the end of the sampling period, the top cover and small end caps are replaced. Samples are transported upright to the laboratory in a rigid container with packing material to prevent jostling or damage. To avoid electrostatic forces from causing fiber loss from the sampling filter, untreated polystyrene foam will not be used for any of the shipping container materials. Collection of a site-specific dust sample will be performed as discussed in Section 8.2.2. This sample needs to be double bagged prior to shipment to avoid any potential cross-contamination. Equipment and supplies utilized with this sampling approach are as follows: • Personal Monitor and Sampling Pump 0.5 to 3 1pm • Battery Pack - Nickel metal hydride battery pack (or equivalent), fitted with a belt clip, compatible with the personal sampling pump. • Filters - Polyvinyl filter (or equivalent hydrophobic membrane filter) supported by a cassette filter holder, 5.0-pm pore size, suitable for connection with the personal monitoring pump system. • Cyclone - SKC Inc. aluminum cyclone (or equivalent) • Medium Flow Rotometer - 0.4 to 4.0 1pm • High Flow Rotometer - 2.0 to 20.0 1pm • Forceps - Nylon, used when handling the filters
10.2.5 Polychlorinated Dibenzodioxins (PCDDs) and Polychlorinated Dibenzofurans (PCDFs)
Ambient air samples will be collected using a General Metals Works (GMW) PS-1 (or performance equivalent) high volume air sampling system equipped for the collection of semivolatile PCDD/PCDF particulate matter on a 102-mm diameter microquartz fiber filter, as well as a glass cylinder containing a polyurethane sorbent (i.e., PUF plug) for the collection of gas phase PCDDs/PCDFs. At each site, one GMW PS-1 sampler will be used to collect PCDD/PCDF samples according to Method TO-9A. Samples will be collected at a flow rate of 200 to 300 liters per minute (1pm) over a sampling period of approximately 24 hours for a resulting total air volume of approximately 288-432 cubic meters (288-432 ma). The PUF (Polyurethane Foam) sampler is a complete air sampling system designed to simultaneously collect suspended airborne particulates as well as trap airborne organic vapors. The PUF sampler is equipped with a bypass blower motor arranged with an independent cooling fan. This feature permits the motor to operate at low sampling flow rates for extended periods without motor failure from overheating. A dual chambered aluminum sampling module contains both filtering systems. The upper chamber supports the airborne particulate filter media in a circular filter holder. The lower chamber encapsulates a glass cartridge, which contains the PUF for vapor entrapment. The voltage variator adjustment screw alters the blower motor speed to
59
CITY_21MC100_003237329
NYC-WTC_000441191
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000437816
Plan document for Environmental Community Air Monitoring at Greenwich and Thames sites, Nov 4, 2005.
95 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000444496
Plan documents for environmental community air monitoring at Greenwich/Thames street sites, Nov 2005.
95 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000441316
Plan for Environmental Community Air Monitoring at Greenwich Street and Thames Street sites, Nov 2005.
93 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000453085
Plan for Greenwich Street and Thames Street monitoring within WTC-related cleanup.
93 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000446622
Part V plan for Environmental Community Air Monitoring at Greenwich/Thames sites.
91 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000446145
Chain-of-custody form for Environmental Community Air Monitoring Program samples at Greenwich/Thames sites.
91 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000448085
Title/approval sheet for Environmental Community Air Monitoring Program and Greenwich/Thames Plan.
91 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000447434
Chain of custody plan for Greenwich Street/Thames Street site air monitoring.
90 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000444945
Plan and submittals for environmental community air monitoring at 133-135 Greenwich and 21-23 Thames.
90 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000440780
Plan document for environmental air monitoring at Greenwich Street and Thames Street sites, dated November 4, 2005.
90 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000443742
Chain-of-custody form for Environmental Community Air Monitoring Program plans at Greenwich Street and Thames Street, dated November 4, 2005.
90 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000426348
Plan document outlining community air monitoring for Greenwich and Thames sites.
91 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000437816
Plan document for Environmental Community Air Monitoring at Greenwich and Thames sites, Nov 4, 2005.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000444496
Plan documents for environmental community air monitoring at Greenwich/Thames street sites, Nov 2005.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000441316
Plan for Environmental Community Air Monitoring at Greenwich Street and Thames Street sites, Nov 2005.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000423370
Plan document for environmental community air monitoring at Greenwich and Thames Street sites, Nov 2005.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000426214
Plan document outlining community air monitoring for Greenwich and Thames sites.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000427582
CoC document for Greenwich/Thames Street air monitoring plan dated Nov 9, 2005.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000437816
Plan document for Environmental Community Air Monitoring at Greenwich and Thames sites, Nov 4, 2005.
Similar indexed content
Plan documents for environmental community air monitoring at Greenwich/Thames street sites, Nov 2005.
Similar indexed content
Plan for Environmental Community Air Monitoring at Greenwich Street and Thames Street sites, Nov 2005.
Similar indexed content
Plan for Greenwich Street and Thames Street monitoring within WTC-related cleanup.
Similar indexed content
Part V plan for Environmental Community Air Monitoring at Greenwich/Thames sites.
Similar indexed content