equipment, through the cleanup operations and satisfactory clearance air sampling results being obtained, or the asbestos project is complete. (2) Timing of Instaiiation. The negative air ventilation units shall be installed and made operational after the critical barriers and isolation barriers are installed. (3) Negative Air Pressure. A negative air pressure, relative to areas outside of the enclosure, shall be maintained at all times in the regulated abatement work area during the asbestos abatement project to ensure that contaminated air in the regulated abatement work area does not escape back to an uncontaminated area. (4) Manometer. A manometer shall be used to document the pressure differential for all OSHA Class I large and small size asbestos project regulated abatement work areas. A minimum of -0.02 column inches of water pressure differential, relative to pressure outside the regulated abatement work area, shall be maintained within the regulated abatement work area, as evidenced by manometric measurements. Once installed, on a daily basis at least twice per workshift, the asbestos abatement contractors supervisor shall document the manometer reading within the daily project log. The manometer shall be installed and made operational once the negative air has been established in the regulated abatement work area. Magnahelic manometers shall be at a minimum calibrated semi-annually, and a copy of the current calibration certification shall be posted at the work site during Phase II operations. (5) Ventilation Units. If more than one primary HEPA-filtered ventilation unit is installed, the units shall be turned on one at a time and the integrity of wall barriers checked for secure attachment or the need for additional reinforcement shall be checked. Units connected in series shall be considered a single unit for this test. A minimum of one additional unit having a capacity of at least equal to that of the primary unit shall be installed as a backup unit to be used upon primary unit failure, or if necessary during primary unit filter changes. (6) Power Supply. A GFCI protected temporary power supply shall be available to satisfy the requirements of the total of all ventilation units. (7) Power Failure. In the event of electric power supply failure, abatement shall stop immediately and shall not resume until power is restored and exhaust units are operating fully. In the event of extended power failure (longer than one hour), after evacuation of all persons from the regulated abatement work area, the decontamination system enclosure facilities shall be sealed airtight. (8) Air Changes. Negative air pressure ventilation equipment shall be installed and operated continuously to provide at least four (4) air changes in the regulated abatement work area every hour including during clearance air sampling.

12 NYCRR56 Subparty, Page 62

CITY_21MC100_003246554

NYC-WTC_000438629

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000438629Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Asbestos, NY DOL reference

NYC-WTC_000441450

Asbestos standards reference page from NY Department of Labor materials.

Similar indexed content

Asbestos sampling chain of custody form

NYC-WTC_000233286

Chain of custody form for asbestos samples referencing New York State Department of Labor regulations and sample tracking details.

Similar indexed content

Compare copies and versions →