NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 134 pages

Environmental plan, Greenwich/Thames Street, 2005

Machine-extracted title · confidence 44%

Plan document for Environmental Community Air Monitoring at Greenwich and Thames sites, Nov 4, 2005.

NYC-WTC_000437816–000437949
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Part V - Quality Assurance Project Plan 133-135 Greenwich Street/21-23 Thames Street Airtek Project 05-0701 - November 4, 2005

larger than the desired size range will be removed from the air flow at the prescribed air flow rate. The units will be equipped with an inlet head to separate PM2.5. Sampling flow rate is critical to maintain the proper particle size cut points of the inlets. Flow rates are maintained at 16.7 liters per minute in the E-BAM monitors using an integral flow meter, pressure sensor, and ambient temperature sensor on board each monitor.

10.2.11 RCRA Waste Sampling

Bulk sample collection of building components for hazard classification will include the following RCRA waste characteristic analytical procedures:

• Ignitability (RCRA waste code DOOl). American Society of Testing Materials (ASTM) method D-93-79 or D-93-80 or D-3278-78. • Corrosivity (RCRA waste code D002). Method 904513 Of 9040C in “Test Methods for Evaluating Solid Waste, Physical/Chemical Methods,” EPA Publication SW-846. NOTE: liquids may be characterized as conosive wastes. • Reactivity (RCRA waste code D003). Analytical methods outlined in sections 7.3.3.2 or 7.3.4.2 of “Test Methods for Evaluating Solid Waste, Physical/Chemical Methods,” EPA Publication SW-846. • Toxicity. The characteristics of toxicity carry the RCRA waste codes of D004 through D043. Each waste code identifies the specific chemical component for which the waste is classified as toxic. The samples to be analyzed for the characteristic of toxicity must be prepared using the Toxicity Characteristic Eeaching Procedures (TCEP) per Method 1311 in “Test Methods for Evaluating Solid Waste, Physical/Chemical Methods,” EPA Publication SW-846. The analytical method applied to the resulting leachate depends on the type of chemical being analyzed for, as follows:

1. Mercury (D009) Method 7470A (aqueous samples) of “Methods for Evaluating Solid Waste, Physical/Chemical Methods,” EPA Publication SW-846Metals/inorganics other than mercury. Method 601 OB or 6020 of “ Methods for Evaluating Solid Waste, Physical/Chemical Methods,” EPA Publication SW-846. 2. TCEP volatile organic compound (VOC) toxic constituents. Method SW846-1311 Method 82603; 3. TCEP semivolatile organic compound (SVOC) toxic constituents, SW846- 1311 Method 8270C; 4. TCEP pesticide and herbicide toxic constituents. Method SW846-1311 8081A and 8151 A.

Building components would generally not be considered as possible RCRA characteristic wastes except for the potential that exists due to impacts by WTC dust. The notable exception to this would be surfaces painted with lead-based paint, which would typically be sampled for TCLP lead analysis. The results of RCRA characteristic analyses, as well

65

CITY_21MC100_003220071

NYC-WTC_000437880

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000437880Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000444496

Plan documents for environmental community air monitoring at Greenwich/Thames street sites, Nov 2005.

Similar indexed content

NYC-WTC_000441133

Plan for Environmental Community Air Monitoring at Greenwich/Thames sites, Nov 2005.

Similar indexed content

NYC-WTC_000441316

Plan for Environmental Community Air Monitoring at Greenwich Street and Thames Street sites, Nov 2005.

Similar indexed content

NYC-WTC_000453085

Plan for Greenwich Street and Thames Street monitoring within WTC-related cleanup.

Similar indexed content

NYC-WTC_000446145

Chain-of-custody form for Environmental Community Air Monitoring Program samples at Greenwich/Thames sites.

Similar indexed content

Compare copies and versions →