Environmental plan, Greenwich/Thames Street, 2005

Machine-extracted title · confidence 44%

Plan document for Environmental Community Air Monitoring at Greenwich and Thames sites, Nov 4, 2005.

NYC-WTC_000437816–000437949
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Part V - Quality Assurance Project Plan 133-135 Greenwich Street/21-23 Thames Street Airtek Project 05-0701 - November 4, 2005

filters provided by the subcontracted laboratory will be placed in each sampling system prior to the start of each sampling event. The air sampler draws up to 400 liters through the filter during each sampling event. The MCE filters will be analyzed for ten (10) metals: antimony, barium, beryllium, cadmium, chromium, copper, lead, manganese, nickel, and zinc. Equipment and supplies utilized with this sampling approach are as follows: • Filters -37mm 0.8um mixed cellulose ester filters. • Area Sampling Pump 2 to 15 1pm. • High-flow Rotometer 2-20 1pm.

10.2.2 Mercury (Gas)

Real-time monitoring for mercury will be performed utilizing an OhioLumex RA 915-1- direct read instrument. The OhioLumex RA 915-1- is a factory-calibrated instrument based on a cold vapor Zeeman atomic absorption analytical process that reduces interference from molecular absorption bands and scattered spectra. A mercury electrodeless discharge lamp (EDL) is used as the radiation source. The sampling system consists of a sample pump operating at 20 L/min. and a multi-path sample cell with an effective path length of 10 meters. Equipment and supplies utilized with this sampling approach are as follows: • OhioLumex RA-915-b Mercury Analyzer - A portable, self-contained field mercury analyzer used to make real time mercury vapor deteraiinations. • Air Intake Hose with Pre-Filter - The sampling line and first pass filter used to remove particulate from the sample gas. • Absorption and Dust Filters - Spare filters used as replacements for the internal particulate and mercury absorbing filters in the instrument.

10.2.3 Asbestos

Asbestos sample collection will be performed in accordance with NIOSH Method 7402 - Asbestos by TEM following the recommendations for personal sampling. Samples will be collected at a rate of six liters per minute (6 1pm) for a minimum of eight (8) hours for a resulting total volume of approximately 2.88 ma. To ensure optimum accuracy, the sampling rate will be adjusted, as needed, to produce a fiber density of 100 to 1,300 fibers/mmi. Pump flow rates of each area sampling pump, with a representative sampler in line, will be measured before and after sample collection. The pump will be run for 10 minutes prior to checking the flow rate. A suitable rotometer (or bubble meter) will be connected to the filter inlet, the flow screw adjusted to the desired sampling value, and the flow rate observed on the rotometer (or bubble meter) will be verified as constant for a minimum of 20 seconds. Flow rates will be recorded on Field Sampling Data Sheets or an equivalent field logbook. Immediately prior to collecting a sample, the sampler will be fastened to a location (i.e., on a tripod) near the individual’s breathing zone, the top cover of the filter cassette cowl extension (“open face”) will be removed and positioned “face down” in the sampler. The joint between the extender and monitor body will be wrapped

57

CITY_21MC100_0 03220063

NYC-WTC_000437872

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000437872Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000444496

Plan documents for environmental community air monitoring at Greenwich/Thames street sites, Nov 2005.

Similar indexed content

NYC-WTC_000441133

Plan for Environmental Community Air Monitoring at Greenwich/Thames sites, Nov 2005.

Similar indexed content

NYC-WTC_000441316

Plan for Environmental Community Air Monitoring at Greenwich Street and Thames Street sites, Nov 2005.

Similar indexed content

NYC-WTC_000453085

Plan for Greenwich Street and Thames Street monitoring within WTC-related cleanup.

Similar indexed content

NYC-WTC_000446145

Chain-of-custody form for Environmental Community Air Monitoring Program samples at Greenwich/Thames sites.

Similar indexed content

Compare copies and versions →