NYC Response Asbestos Air Sampling Results for Staten island Landfill Sampling Date and Time 5/7/20Q2Q800 to 5/8/2Q02 0619 Date VaSidatioii Date; 05/16/2002

PCM by NiOSH 7400 ___________ TEM ( AHERA) Sampling Sampling Sample Structures (#) Date Sample No. Location Volume* Matrix f/mm^ f/cc O.Sp - 5p 5!^ S/mm" S~f/CC‘* 05/07/02 LF04504 P-1 2174.30 Air <7.0 <0.001 0 0 <19.69 <0.0035 05/07/02 LF04505 P-2 1778.20 Air <7.0 <0.002 0 0 <19.69 <0.0043 05/07/02 LF04506 P-3 1207.80 Air <7.0 <0.002 0 0 <13.12 <0.0042 05/07/02 LF04507 P-4 1296.00 Air <7.0 <0.002 0 0 <15.75 <0.0047 05/07/02 LF04508 P-5 1233.75 Air <7.0 <0.002 0 0 <13.12 <0.0041 05/07/02 LF04509 P-6 1989.00 Air <7.0 <0.001 0 0 <19.69 <0.0038 05/07/02 LF04510 P-7 1296.00 Air <7.0 <0.002 0 0 <15.75 <0.0047 05/07/02 LF04511 P-8 1296.00 Air <7.0 <0.002 0 0 <15.75 <0.0047 05/07/02 LF04512 W-12A 1296.00 Air <7.0 <0.002 0 0 <15.75 <0.0047 05/07/02 LF04513 W-12B 1114.75 Air <7.0 <0.002 0 0 <13.12 <0.0045 05/07/02 LF04514 B-13 1296.00 Air <7.0 <0.002 0 0 <15.75 <0.0047 05/07/02 LF04515 B-14 1188.00 Air 73.89 0.024 0 0 <13.12 <0.0043 05/07/02 LF04516 T-15 1296.00 Air 16.56 0.005 0 ....l 15.75 0.0047 05/07/02 LF04517 T-16 1296.00 Air 8.92 0.003 0 0 <15.75 <0.0047 05/07/02 LF04518 0-17 1296.00 Air <7.0 <0.002 0 0 <15.75 <0.0047 05/07/02 LF04519 0-18 1296.00 Air <7.0 <0.002 0 0 <15.75 <0.0047 05/07/02 LF04520 0-19 1296.00 Air <7.0 <0.002 0 0 <15.75 <0.0047 05/07/02 LF04522 Lot Blank 0.00 Air <7.0 n/a NA'"> NA'2> NA'2> NA® 05/07/02 LF04523 Trip Blank 0.00 Air <7.0 n/a NA<=^> NA<=> NA<=> NA<=>

No sample was submitted to MPHS 20 due to pump fault. Please note that sample # P1 ran for over 21 hours. Please note that sample # P2 ran for over 17 hours. Please note that sample # P6 ran for over 18 hours.

Key; * Some sample volume (liters) are below recommended limit for the TEM method; volume is based on pump reading ** Structure (S) is roughly equivalent to fiber (f) *** Chrysotile **** Actinolite ““‘Amosite NA - Not analyzed due to overloading of particulates NA - Not analyzed for TEM NA - Not analyzed due to wet filter n/a - Not applicable NR - Not requested O NS - Sample not submitted H R - Sample data rejected due to no sample volume NC - Sample not collected to NS - Sample not submitted

S NiOSH 7400: Fiber Anaiysis of Air samples via NIOSH 7400, Revision 3, issue 2, 8/15/94 o Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) EPA 40GFR Part 763 (AHERA) o o I Ln o o to

o Ur* rc co

NYC-WTC_000437281

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000437281Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →