NYC 9/11 Public Portal Document
Respirable Silica: The overwhelming majority of 1160 silica samples (excluding bulk and
blank samples) show no detectable levels of airborne silica. However, 77 exposures
exceeded the PEL. The highest sample result was approximately twenty-one times the
OSHA limit (jack hammering concrete 16 feet below grade). The other elevated exposures
were approximately one to fourteen times the OSHA limit. These exposures occurred
during: 1) pre-drilling /slurry wall 2) jack hammering, 3) rubble removal and loading
operations near the Winter Garden; 4) during the breaking up of concrete in the pit; 5) while
drilling the concrete slurry wall, 6) flagging operations in pit, and 7) while chipping concrete
with power tools during demolition activities at 7 WTC’s parking garage. Most of the work
areas where apparent overexposures to silica occurred were in the rubble pile/pit; an area
where OSHA continues to encourage the use of respiratory protection.
Organic
Compounds: OSHA has taken a total of 699 samples (excluding bulk and blank samples)
for organic compounds such as acetaldehyde, acrolein, acrylonitrile, benzene,
2-butanone, carbofurans, dioxin, PCBs, ethyl benzene, formaldehyde. Freon R-22
(chlorodiflouromethane), hexone, isocyanates (e.g. MDl, TDl), perchloroethylene,
polynuclear aromatics, phosgene, styrene, toluene, 1-3 butadiene, trichloroethylene,
vinyl chloride, glutaraldehyde, and xylene. Screening samples initially showed
elevated levels of some organic chemicals resulting from the fires burning in the
rubble pile. Subsequent personal and area samples show worker exposure levels to
be below OSHA limits. However, one personal sample result for a benzene sample
taken was found to be at the 8-hr. OSHA Allowable Limit concentration of 1 ppm.
This was found on a backhoe operator moving debris on 10/7/01. See information
below for the specific counts in regards to polynuclear aromatics. Freon R-22,
phosgene and dioxin.
Dioxins: OSHA has taken 10 dioxin samples (excluding blanks) in the plume over
hot spots in (and around the perimeter of) the rubble pile. Dioxin levels detected
around the perimeter are lower than those found directly over the pile. To date, only
one sample taken on the rubble pile showed dioxin levels which exceeded
background levels. Dioxins are considered collectively as suspect human
carcinogens. OSHA does not have a PEL for dioxins.
2
CITY_21MC100_003254173
NYC-WTC_000437236
OCR can misread numbers and units. Confirm readings against the page image before using them.