NVC Response Asbestos Air Sampiing Results for WTC Extended Network Sampling Date and Time: 11/28/01 1200 to 2400 Data Validation Date: 12/03/2001
PCM by «!OSH 7400 ___________ TEM: AHERA) Sampling Sampiing Sample S/tfuctures (#) l Date Sampie No. Location Voiume (L)" Matrix f/mm^ ?/cc 0.5p" 5p 5p S/mm® S~f/cc*
11/28/01 ^093-18-0062 Park Row 754’ Air <7.0 <0.004 0 0 <8.89 <0.0045 11/28/01 ^093-19-0062 BMCC .*** 826’ Air 7.01 0.003 0 0 <8.89 <0.0041 11/28/01 ^093-20-0062 Coast Guard 822’ Air <7.0 <0.003 0 0 <10.00 <0.0047 11/28/01 ^093-15-0061 ihattan PS # 1252 Air <7.0 <0.002 0 0 <16.00 <0.0049 11/28/01 ^094-09-0053ironx PS #15- 1292 Air <7.0 <0.002 0 0 <16.00 <0.0048 11/28/01 ^096-12-0056 jeens PS #15 1380 Air <7.0 <0.002 0 0 <16.00 <0.0045 11/28/01 ^095-98-0056 joklyn PS #2 1440 Air <7.0 <0.002 0 0 <16.00 <0.0043 11/28/01 ^097-18-005£en Island PS 1440 Air <7.0 <0.002 0 0 <16.00 <0.0043
Key: NS: Not sampled ‘Structure (S) roughly equivalent to fiber (f) ** Sample volume is based on pump reading *** Sample volume is below recommended limit for TEM analysis NA<^>: not analyzed due to overloading of particulates NA<i>: not analyzed for TEM ‘ Chrysotile Sample volume is below recommended limit for TEM analysis ****‘ Chrysotile NR - analysis not requested NS - Sample not submitted for analysis n/a - Not applicable
Q NIOSH 7400: Fiber Anaiysis of Air samples via NIOSH 7400, Revision 3, Issue 2, 8/15/94 H Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) EPA 40CFR Part 763 (AHERA) l"^ Standard criteria: EPA 40CFR Part 763 (AHERA): 0.01 fiber/cc (PCM), 70 S/mm^ volume 1200 L, for 25 mm filter (TEM) to
S o o o I L_ o o to
o o
NYC-WTC_000437205
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000437221
NVC/LD asbestos sample results with PCM/TEM data across NYC locations including Manhattan.
3 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000437343
Asbestos test results (PCM/TEM) for WTC area samples, Jan 2002.
4 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000452692
NVC/WS asbestos sampling results for WTC area; PCM and TEM results 12/12/01.
4 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000438679
NVC asbestos results for WTC Manhattan samples, December 2001, with PCM/TEM data.
4 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000436271
Asbestos air sampling results for WTC-related sites by PCM/TEM.
4 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000436185
WTC asbestos sampling results with PCM/TEM fiber counts by sample.
4 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000436313
WTC asbestos testing results in January 2002, including PCM/TEM data.
4 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000232883
Laboratory report listing asbestos air sampling results from the WTC area collected on January 10, 2002.
4 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000436488
WTC-related asbestos sampling results with TEM/PCM data, 01/08/02.
4 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000454221
Staten Island/NYC response asbestos sampling results for various locations; includes sample IDs and results.
3 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000436274
Asbestos air sampling results at multiple NYC locations related to WTC work.
4 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000419568
Asbestos sampling results for WTC locations, Jan 24, 2002.
4 shared non-person entities · 1 shared topics · similarity 0.993
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000452692
NVC/WS asbestos sampling results for WTC area; PCM and TEM results 12/12/01.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000438679
NVC asbestos results for WTC Manhattan samples, December 2001, with PCM/TEM data.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000436271
Asbestos air sampling results for WTC-related sites by PCM/TEM.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000437343
Asbestos test results (PCM/TEM) for WTC area samples, Jan 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000436185
WTC asbestos sampling results with PCM/TEM fiber counts by sample.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000436313
WTC asbestos testing results in January 2002, including PCM/TEM data.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000452692
NVC/WS asbestos sampling results for WTC area; PCM and TEM results 12/12/01.
Similar indexed content
NYC-WTC_000437221
NVC/LD asbestos sample results with PCM/TEM data across NYC locations including Manhattan.
Similar indexed content
NYC-WTC_000438679
NVC asbestos results for WTC Manhattan samples, December 2001, with PCM/TEM data.
Similar indexed content
NYC-WTC_000436271
Asbestos air sampling results for WTC-related sites by PCM/TEM.
Similar indexed content
NYC-WTC_000437343
Asbestos test results (PCM/TEM) for WTC area samples, Jan 2002.
Similar indexed content