NYC 9/11 Public Portal Document
Submitted to American Industrial Hygiene Association. October 2, 2001
taken to understand each method’s limitations as well as its reliabihty and suitability for a
specific measurement set of conditions (Yamate, 1984; Chang, 1987)). Failure to
correctly select the proper method, or failure to properly weigh the significance of
resulting data, based on method limitations, may result in incorrect estimation of actual
worker exposures and corresponding health risk. In this specific case it is particularly
important since the particle size of the overloading non-asbestos material is of the same
size as the fiber length of the thin asbestos fibers. The increased particulate load requires
thicker carbon films for support which in turn compromises proper identification of the
thinnest fibers by selected area electron diffraction (SAED).
The data presented in this report suggest that some surface residues deposited as a result
of the fire and collapse of the WTC towers contain asbestos in the range of 0.25 - 0.75%.
Additionally, the particle size of the surface residue is very fine (and dry), a condition not
typically encountered during routine asbestos removal projects. Furthermore, the asbestos
present at a concentration of approximately 1 % is only a small fraction of the total mass
of the surface residue, a residue that is a fine and dry powder. There is every indication,
and it is reasonable to assume, that under commonly encountered conditions the
components of the fine surface residue will become airborne and thus available for
inhalation by workers. Under conditions where rapid dilution of the air does not occur,
such as within building structures, it should be anticipated that very small asbestos fibers
may become airborne and remain in the breathing zone of workers for extended periods.
This condition will most likely occur inside buildings that have been contaminated with
surface residues generated by the collapsed office buildings. This is evident in the data
produced by the TEM method that detected asbestos fibers (asbestos structures) less than
or equal to (<) 5 pm in length at elevated concentrations in indoor air.
Airborne asbestos fiber concentrations estimated by Phase Contrast Microscopy (PCM)
(NIOSH method 7400) are useful when particle size is large, non-fiber particle loading is
light, and measured atmospheres are assumed to be dominated by asbestos fibers. In
cases when fiber size is small and the concentration is low, PCM analysis may
underestimate the asbestos fiber concentration. In contrast, when non-asbestos fibers
dominate the atmosphere PCM analysis may overestimate the asbestos fiber
concentration. For these reasons, application of PCM analysis is best suited for routine
compliance screening of asbestos abatement practices and may not be applicable to
investigations such as those conducted at the WTC site. A review of the comparison
between PCM/TEM data presented in Table 6 illustrates the limitation of PCM analysis
for investigations of atmospheres such as those encountered at the WTC site. Generally,
health hazard assessors look at both TEM and PCM data when performing assessments
with the understanding that TEM is recognized as providing the most complete data
about exposure to asbestos fibers.
During the performance of testing for this preliminary health hazard evaluation, care was
taken to perform all methods under strict adherence to published procedures. These
procedures were appropriately modified when sample backgrounds exceeded the
tolerance of the method. This level of care was a recognition of the unique condition
presented by the composition and particle size profile of the surface residue as
Page - 6
CITY_21MC100_008112797
NYC-WTC_000437060
OCR can misread numbers and units. Confirm readings against the page image before using them.