NYC 9/11 Public Portal Document
Submitted to American Industrial Hygiene Association. October 2, 2001
approximately two city blocks from the focal point and a second approximately four city
blocks along the radian. A graphical depiction of the sample location plan is presented in
figure 2. A number was assigned to each location (as noted in figure 1) and this number
is used as a descriptor for each sample of surface residue.
Subsequently, eleven air samples were collected within two building structures located
near the collapsed WTC towers. Building structure A sustained limited damage but some
areas of the lower floors were littered with paper debris and were coated with a layer of
surface residue (see figure 5) . Building structure B sustained major damage with most
areas littered with paper debris and coated with a layer of surface residue. Air samples
within these two buildings were collected using 25 mm diameter, banded AHERA TEM
cassettes (0.45 pm pore size mixed cellulose ester collection filter plus 5 pm pore size
diffusion filter and cellulose support pad) (Zefon Analytical Accessories). Air sampling
pumps (Gillian model/PN 800845) were calibrated at 2.0 liters per minute (EPM) and
collection times varied with total air volumes ranging from 488 - 558 liters. Air sample
locations are listed in Table 1. During air sample collection within Building A, routine
loading and unloading of equipment was occurring in the loading dock area, routine
office work was being performed within the 3”''’ floor office, debris removal associated
with the repair of broken windows was occurring in the 11“* floor office, and no work was
being performed in the 36* floor office where windows were still intact. During air
sample collection in Building B, no work was being conducted in the 3"* floor office
space but contractors staged their various repair activities in the 3”'‘* floor staging area. On
upper floors (6* and 9*) of Building B, debris removal associated with preparations to
repair broken windows was underway during air sample collection, with this activity
concentrated on the 6* floor.
Asbestos content of the surface residue was determined by PLM using EPA method
600/R-93/116 dated July 1993 with visual volume estimation of the weight/weight
percentage (w/w%) of asbestos. Quantitation of asbestos content was also determined
independently for all samples of surface residue using the EPA 400 point count method.
Particle characterization was performed by MVA, Inc. in the following manner (Millette,
2001). The dust samples were characterized by both gravimetric measurement of sieve
size fractions and by microscopical analyses. The samples were sieved using standard 4-
inch diameter brass sieves (U.S. Standard Sieve Mesh #s 50 and 200). The gravimetric
determinations were made of the following size fractions: >300pm, 75 - 300pm, and
<75pm. The fractions were combined and examined by stereomicroscopy utilizing a
Zeiss Stemi 2000 stereomicroscope having a magnification range from 6.5X to 47X.
The components of the samples were then analyzed utilizing an Olympus BH-2 polarized
light microscope (PEM) having a magnification range from 40X to lOOOX. A visual
estimate was made of the relative percentage by volume of loosely aggregated separable
fibrous lint (hair + natural fibers + manmade fibers). Each identified constituent was
rated as to whether it was "common" (consistently found throughout the sample) or
"present" (detected but infrequently). The fine portions were analyzed by scanning
electron microscopy (SEM) and transmission electron microscopy. The SEM analysis
was done with a JEOE 6400 equipped with a Noran Voyager energy dispersive x-ray
Page - 3
CITY_21MC100_008112794
NYC-WTC_000437057
OCR can misread numbers and units. Confirm readings against the page image before using them.