NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 5 pages

DOH asbestos testing results in lower Manhattan buildings

Machine-extracted title · confidence 57%

DOH letter explaining asbestos test results in building interiors and surrounding areas.

NYC-WTC_000436856–000436860
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Summary of Asbestos Sampling Results Page 2 of 3 Address: 70 Battery Place Date sampled: November 19, 2001

Area Sampled Outside Common Residence 1 Residence 2 Sample Numbers A-O-10 A-C-10 A-Rl-10 A-R2-10

Concentration of Fibers 0.001 0.002 0.001 0.001 (f/cc)* at 70 Battery Pl.

Concentration of Fibers <0.001 to 0.001 <0.001 to 0.002 <0.001 to 0.003 <0.001 to 0.003 (f/cc) in Homes Above 59“* St. (background locations) NYC Re-occupancy 0.01 0.01 0.01 0.01 Standard (f/cc) * f/cc is fibers in each cubic centimeter (cc) of air. This is calculated from the number of fibers seen on the air filter and the volume of air pulled through the filter measured in cubic centimeters of air.

ASBESTOS DUST TEST RESULTS

The dust and debris samples were examined by two different laboratory methods for asbestos fibers, Polarized Light Microscopy (PLM) and Transmission Electron Microscopy (TEM). PLM is used to define asbestos containing material in dust and debris. A material is considered to be asbestos containing material if it contains more than 1% asbestos using the PLM method. The PLM method only counts the larger asbestos fibers. Therefore, if results by PLM were not greater than 1% asbestos, the sample was then analyzed by the TEM method that does count the smaller fibers. However, TEM analysis is not used for regulatory purposes for dust samples.

While a low level of asbestos was detected in some of the dust samples from your building, this was only from the dust samples from outside and in a small area of the lobby. Low levels of asbestos (less than 1%) were found in one visible dust outdoor sample. Slightly higher levels were found (1.5%) in a vacuum dust in the lobby, although no visible dust was observed. However, since there is variability in laboratory analyses, the sample with 1.5% asbestos was reanalyzed and upon reanalysis, levels were <1% asbestos. No asbestos fibers were found in the dust samples from the two residences.

Fibrous materials in dust found by PLM Analysis: Polarized Light Microscopy identifies asbestos fibers by shape and optical characteristics. Other fibers such as fabric (synthetics), paper (cellulose) and fiberglass may be identified in the analysis. The laboratory analyst will count the fibers present to give an estimate of fiber content as a percent. PLM is used for regulatory purposes for dust samples.

Iavpa Samnipd Outside** I Common I Residence 1 I Residence 2 I Outside

CITY_21MC100_003155801

NYC-WTC_000436859

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000436859Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →