Summary of Asbestos Sampling Results Page 2 of 3
Address: 70 Battery Place Date sampled: November 19, 2001
Area Sampled Outside Common Residence 1 Residence 2
Sample Numbers A-O-10 A-C-10 A-Rl-10 A-R2-10
Concentration of Fibers 0.001 0.002 0.001 0.001
(f/cc)* at 70 Battery Pl.
Concentration of Fibers <0.001 to 0.001 <0.001 to 0.002 <0.001 to 0.003 <0.001 to 0.003
(f/cc) in Homes Above
59“* St. (background
locations)
NYC Re-occupancy 0.01 0.01 0.01 0.01
Standard (f/cc)
* f/cc is fibers in each cubic centimeter (cc) of air. This is calculated from the number of fibers seen on the air filter
and the volume of air pulled through the filter measured in cubic centimeters of air.
ASBESTOS DUST TEST RESULTS
The dust and debris samples were examined by two different laboratory methods for asbestos
fibers, Polarized Light Microscopy (PLM) and Transmission Electron Microscopy (TEM). PLM
is used to define asbestos containing material in dust and debris. A material is considered to be
asbestos containing material if it contains more than 1% asbestos using the PLM method. The
PLM method only counts the larger asbestos fibers. Therefore, if results by PLM were not
greater than 1% asbestos, the sample was then analyzed by the TEM method that does count the
smaller fibers. However, TEM analysis is not used for regulatory purposes for dust samples.
While a low level of asbestos was detected in some of the dust samples from your building, this
was only from the dust samples from outside and in a small area of the lobby. Low levels of
asbestos (less than 1%) were found in one visible dust outdoor sample. Slightly higher levels
were found (1.5%) in a vacuum dust in the lobby, although no visible dust was observed.
However, since there is variability in laboratory analyses, the sample with 1.5% asbestos was
reanalyzed and upon reanalysis, levels were <1% asbestos. No asbestos fibers were found in the
dust samples from the two residences.
Fibrous materials in dust found by PLM Analysis: Polarized Light Microscopy identifies
asbestos fibers by shape and optical characteristics. Other fibers such as fabric (synthetics),
paper (cellulose) and fiberglass may be identified in the analysis. The laboratory analyst will
count the fibers present to give an estimate of fiber content as a percent. PLM is used for
regulatory purposes for dust samples.