http://pubs.acs.orq/imaqes/entities/mqr.qifq/m ^. The caveats noted in the previous dioxin discussion regarding the conversion of concentration values to surface loading values also apply in this instance.

Analytes with Limited Comparison Studies. As indicated earlier, several analytes did not have literature values that could be used for direct comparison, specifically, SVF in settled dust and alpha-quartz in air and settled dust. The data reported here for these analytes may be useful for future hazardous site evaluations as there is a paucity of data reported in the literature for these analytes. In addition, these data may help better characterize residential indoor environments for health-related studies or for cleanup programs in response to indoor contamination.

As shown in Table 5, building-related materials that were included in this study (i.e., cristobalite, tridymite, gypsum, and portlandite) were infrequently detected in settled dust, and none were detected in the air. Detection limits for these compounds were established from parameters based upon the ultimate sensitivity of the analytical equipment (X-ray Diffractometer) and the sample preparation protocols detailed in each specific analytical method. To achieve lower detection limits applicable for estimating background concentrations for these analytes, major modifications to the analytical procedures or the sampling methods would have to have been made.

Differences between Residential and Common Spaces. There were some differences observed between the residential spaces and the common spaces, both in frequency of detection and in the measured concentrations. A variety of factors may influence these differences, such as activity patterns, amount of foot traffic, type, and frequency of cleaning. These factors may differ between these spaces, and some combination of these factors may be responsible for this observation. Although there are physical and usage differences between residential and common spaces, the overall results were similar for the two types of spaces. Therefore, assessing exposure to contaminants in indoor environments, at least in this limited study, the results for the two different spaces were combined to estimate concentrations to which an individual may be exposed on a daily basis.

In summation, we initiated this study due to the limited historical background concentrations on building-related materials and combustion byproducts in residential dwell ings. We characterized concentration ranges for select building-related materials and combustion byproducts that were identified in WTC-related dust. This provided insight into preexisting concentrations in residential dwellings for these analytes prior to the collapse of the WTC. Where historical data were available, a comparative analysis showed general agreement with these background values reported in the literature.

CITY_21MC100_009137581

NYC-WTC_000436543

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000436543Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000320385

Oldraft report for World Trade Center background study prepared for FEMA, EPA Region 2.

Similar indexed content

NYC-WTC_000418482

WTC background study interim final report prepared for FEMA and EPA contractors.

Similar indexed content

Compare copies and versions →