NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 7 pages

EMSL analytical SEM/XRD methods supplement

Machine-extracted title · confidence 41%

Memorandum outlining analytical methods for SEM, XRD, and related techniques used on WTC dust.

NYC-WTC_000436260–000436266
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

Z Z o o co g o I o EMSL Analytical, Inc. -107 Hadden Avenue - WestmfM. NJ. OSW “0 c o CT o o' Ca5 "0 o> o ro o> 03 ro EPA Residential Air Sampling for MMVF, Supplement #4 22-Mar-02 O o o c 3 Test Type: Particle Size for Air Quality Surveys o 3 Matrix: Air, Dust or Bulk Particle size is routinely used to determine HVAC efficiency. Filters in the venting system are continually bombarded by particles that can damage the filter or clog the pores causing pressure to tear or unseat the filter releasing particles into the air stream. Improper installation and manufacturer defects are also among the reasons that particles may not be captured.

Samples collected with O.lpm Polycarbonate filters at the registers and the intake using 10 1pm for a total volume of 1,500+ liters are analyzed. The results are reported in particle size vs. concentration. This information can help to determine if the filter is collecting the appropriate size particles or if there is damage within the system. Ir Open Face Particle Size Analysis Cassette 1200

1000 Particle sizing can be tailored to your individual needs such as 800 ZJ specific size ranges, specific particle types and even full 8 identification of the particles present. For simple particle size o 600 “b measurements your flow rate can vary from 5 to 15 liters per 400 minutes. Over loading the filter is not as crucial as many tests. E Duration of sampling can be as long as you like provided the flow ZJ z 200 rate does not start to decline. A change to the flow rate is an o indication of filter clogging that will effect the results. H o K o o Particle Sizing by SEM can also be used to determine the size I o to distribution of particles in dust. It can also be used to determine if S O Size in (urn) 0 Intake 0 Return a specific particle, such as silica, is with a specified range. o o The chart shows that this system virtually eliminates particles greater than 3 microns. I This system met the manufacturer's claims as seen in the relationship between the o co particle sizes entering the intake vs. those returning to the associated rooms. co CD o co OS

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000436262Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

MMVF sampling guidance, EMSL

NYC-WTC_000389091

Discussion of MMVF sampling, microscopy methods, and source tracing for contamination.

Similar indexed content

Compare copies and versions →