NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 19 pages

WTC unoccupied building monitoring documentation, 2002

Machine-extracted title · confidence 50%

Documentation for building monitoring program at 125 Cedar Street by DEP and ATC.

NYC-WTC_000435300–000435318
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Final Report 125 Cedar Street, NYC, NY

Wipe Sampling

The wipe sampling was performed consistent with generally accepted industrial hygiene practices. There were inherent limitations created by constraints of time, operational and work practice variability, variations in contaminant concentrations, and samphng and analytical accuracy. The results of the sampling represent conditions found on the dates the samples were collected.

There are no established regulatory values for these analytes on surfaces.

Wipe Sample Results

Background and clearance wipe sampling was performed consistent with generally accepted industrial hygiene practices. There were inherent limitations created by operational and work practice variability, variations in contaminant concentrations, and samphng and analytical accuracy. All acceptable results of the sampling represent conditions found on the dates the samples were collected. Individual analytes specified herein were analyzed in accordance with the project specifications utilizing the following analytical procedures:

• Lead, EPA Method SW-846-6010B • PAHs, ASTM-6661-01, EPA Method SW-846-8270C • Dioxin, ASTM-6661-01, EPA Method SW-846-8290 • Mercury, EPA Method SW-846-7471A

Conclusions

Based on project oversight, including results of air sampling and wipe sampling data collected, it is the professional opinion of ATC that all cleaning at 125 Cedar Street, New York, New York was conducted in accordance with the project manual as well as all applicable federal, state and local asbestos regulations. All ambient and final air clearance and wipe sample results were found to have a concentration satisfactory to achieve the acceptable criteria established by the NYCDEP and EPA standards for re­ occupancy following cleaning activities.

Our professional services have been performed, our findings obtained and our recommendations prepared in accordance with customary principles and practices in the field of environmental science and engineering in this region. This statement is in lieu of other statements either expressed or implied. This report does not warrant against future operations or conditions, nor does it warrant against operations or conditions present of a type or at a location not investigated.

This report is intended for the sole use of the NYCDEP and USEPA. The scope of

ATC Project No. 15.22906.0002 Page 6

CITY_21MC100_009480125

NYC-WTC_000435308

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000435308Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000446593

Final laboratory TEM air analysis report for WTC unoccupied building monitoring at 125 Cedar Street.

Similar indexed content

Compare copies and versions →