NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 100 pages

Asbestos SOP/Appendix excerpt, Part 763 (EPA)

Machine-extracted title · confidence 32%

Page from Part 763 asbestos standard; references to testing and enforcement sections.

NYC-WTC_000433711–000433810
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Pt. 763. Subpt. E. App. E 40 CFR Ch. I (7-1-00 Edition) recently directed a major research effort to­ 2.5.2 Sample Analysis ward the preparation and characterization of analytical reference materials, including as­ Sample analysis requirements include an bestos standards; 1^17 however, these are not X-ray diffraction unit, equipped with: available in large quantities for routine • Constant Potential Generator: Voltage and analysis. mA Stabilizers In addition, the problem of ensuring the • Automated Diffractometer with Step-Scanning comparability of standard reference and Mode sample materials, particularly regarding • Copper Target X-Ray Tube: High intensity, crystallite size, particle size distribution, fine focus, preferably. and degree of crystallinity, has yet to be • X-Ray Pulse Height Selector adequately addressed. For example, Langer • X-Ray Detector (with high voltage power et al.have observed that in insulating mat­ supply): Scintillation or proportional rices, chrysotile tends to break open into counter. bundles more frequently than amphiboles. • Focusing Graphite Crystal Monochromator: or This results in a line-broadening effect with Nickel Filter (if copper source is used, and a resultant decrease in sensitivity. Unless iron fluorescence is not a serious prob­ this effect is the same for both standard and lem) . sample materials, the amount of chrysotile • Data Output Accessories: in the sample will be underestimated by • Strip Chart Recorder XRD analysis. To minimize this problem, it • Decade Scaler/Timer is recommended that standardized matrix re­ • Digital Printer duction procedures be used for both sample and standard materials. • Sample Spinner (optional). • Instrument Calibration Reference Specimen: 2.4 Precision and Accuracy ce-quartz reference crystal (Arkansas quartz standard, #180—147—00, Philips Elec­ Precision of the method has not been de­ tronics Instruments, Inc., 85 McKee Drive, termined. Mahwah, NJ 07430) or equivalent. Accuracy of the method has not been de­ termined. 2.6 Reagents 2.5 Apparatus 2.6.1 Standard Reference Materials 2.5.1 Sample Preparation The reference materials listed below are Sample preparation apparatus require­ intended to serve as a guide. Every attempt ments will depend upon the sample type should be made to acquire pure reference under consideration and the kind of XRD materials that are comparable to sample ma­ analysis to be performed. terials being analyzed. • Mortar and Pestle: Agate or porcelain. • Chrysotile: UICC Canadian, or• NIEHS • Razor Blades Plastibest. (UICC reference ]materials • Sample AHU: SPEX, Inc., freezer mill or available from: UICC, MRC Pneumo­ equivalent. coniosis Unit, Llandough Hospital, • Bulk Sample Holders Penarth, Glamorgan, CF61XW, UK). • Silver Membrane Filters: 25-mm diameter, • Crocidolite: UICC 0.45-ji m pore size. Selas Corp, of America, • Amosite: UICC Flotronics Div., 1957 Pioneer Road, Hun­ • Anthophyllite: UICC tington Valley, PA 19006. • Tremolite Asbestos: Wards Natural Science • Microscope Slides Establishment, Rochester, N.Y.; Cyprus • Vacuum Filtration Apparatus: Gelman No. Research Standard, Cyprus Research, 2435 1107 or equivalent, and side-arm vacuum Military Ave., Los Angeles, CA 90064 flask. (washed with dilute HCl to remove small • Microbalance amount of calcite impurity); India • Ultrasonic Bath or Probe: Model W140, tremolite, Rajasthan State, India. Ultrasonics, Inc., operated at a power den­ • Actinolite Asbestos sity of approximately 0.1 W/mL, or equiva­ lent. 2.6.2 Adhesive • Volumetric Flasks: 1—I. volume. • Assorted Pipettes Tape, petroleum jelly, etc. (for attaching • Pipette Bulb silver membrane filters to sample holders). • Nonserraied Forceps • Polyethylene Wash Bottle 2.6.3 Surfactant • Pyrex Beakers: 50-mL volume. 1 percent aerosol OT aqueous solution or • Desiccator equivalent. • Filter Storage Cassettes • Magnetic Stirring Plate and Bars 2.6.4 Isopropanol • Porcelain Crucibles • Muffle Furnace or Low Temperature Asher ACS Reagent Grade.

734

CITY_21MC100_011989141

NYC-WTC_000433796

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000433796Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →