NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 100 pages

Asbestos SOP/Appendix excerpt, Part 763 (EPA)

Machine-extracted title · confidence 32%

Page from Part 763 asbestos standard; references to testing and enforcement sections.

NYC-WTC_000433711–000433810
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Pt. 763. Subpt. E. App. E 40 CFR Ch. I (7-1-00 Edition) land deed or other record along with a notice an extent sufficient to cause confusion in waining against excavation of the aiea. identification. Procedures that may be used for the removal of interferences aie pre­ [52 FR 41897, Oct. 30, 1987, as amended at 62 sented in Section 1.7.2.2. FR 1834, Jan. 14, 19971 1.4 Precision and Accuracy Appendix E to Subpart E—Interim Adequate data for measuring the accuracy IVteTHOD OF THE DETERMINATION OF and precision of the method for samples with Asbestos in Bulk Insulation Sam­ various matrices are not currently available. ples Data obtained for samples containing a sin­ gle asbestos type in a simple matrix are SFCTTON 1 , POT ARTZFD T JOHT MTCROS(^PV available in the EPA report Bulk Sample 1.1 Principle and Applicability Analysis for Asbestos Content: Evaluation of the Tentative Alethod.-^ Bulk samples of building materials taken for asbestos identification arc first examined 1.5 Apparatus for homogeneity and preliminary fiber iden­ tification at low magnification. Positive 1.5.1 Sample Analysis identification of suspect fibers is made by A low-power binocular microscope, pref­ analysis of subsamplcs with the polarized erably stereoscopic, is used to examine the light microscope. bulk insulation sample as received. The principles of optical mineralogy arc • Microscope: binocular, 10-45X (approxi­ well established.” A light microscope mate). equipped with two polarizing filters is used • Light Source: incandescent or fluorescent. to observe specific optical characteristics of • Forceps, Dissecting Needles, and Probes a sample. The use of plane polarized light al­ • Glassine Paper or Clean Glass Plate lows the determination of refractive indices Compound microscope requirements: A po­ along specific crystallographic axes. Mor­ larized light microscope complete with po­ phology and color arc also observed. A retar­ larizer, analyzer, port for wave retardation dation plate is placed in the polarized light plate, 360° graduated rotating stage, substage path for determination of the sign of elon­ condenser, lamp, and lamp iris. gation using orthoscopic illumination. Ori­ • Polarized Light Microscope: described above. entation of the two filters such that their vi­ • Objective Lenses: lOX, 20X, and 40X or near bration planes arc perpendicular (crossed equivalent. polars) allows observation of the birefring- • Dispersion Staining Objective Lens (optional) cncc and extinction characteristics of aniso­ • Ocular Lens: lOX minimum. tropic particles. • Eyepiece Reticle: cross hair or 25 point Quantitative analysis involves the use of Chalkley Point Array. point counting. Point counting is a standard • Compensator Plate: 550 millimicron retarda­ technique in petrography for determining tion. the relative areas occupied by separate min­ erals in thin sections of rock. Background 1.5.2 Sample Preparation information on the use of point counting^ Sample preparation apparatus require­ and the interpretation of point count data^ ments will depend upon the type of insula­ is available. tion sample under consideration. Various This method is applicable to all bulk sam­ physical and/or chemical means may be em­ ples of friable insulation materials sub­ ployed for an adequate sample assessment. mitted for identification and quantitation of • Ventilated Hood or negative pressure glove asbestos components. box. 1.2 Range • Microscope Slides • Coverslips The point counting method may be used • Mortar and Pestle: agate or porcelain, (op­ for analysis of samples containing from 0 to tional) 100 percent asbestos. The upper detection • Wylie Mill (optional) limit is 100 percent. The lower detection • Beakers and Assorted Glassware (optional) limit is less than 1 percent. • Certrifuge (optional) • Filtration apparatus (optional) 1.3 Interferences • Low temperature asher (optional) Fibrous organic and inorganic constituents of bulk samples may interfere with the iden­ 1.6 Reagents tification and quantitation of the asbestos 1.6.1 Sample Preparation mineral content. Spray-on binder materials may coat fibers and affect color or obscure • Distilled Water (optional) optical characteristics to the extent of • Dilute CH3COOH: ACS reagent grade (op­ masking fiber identity. Fine particles of tional) other materials may also adhere to fibers to • Dilute HCl: ACS reagent grade (optional)

726

CITY_21MC100_011989133

NYC-WTC_000433788

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000433788Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →