REGION 1's BENCHMARK FOR SETTLED ASBESTOS DUST

EPA Region 1 derived a benchmark, or a safe level, for asbestos in settled dust in order to justify asbestos levels found in the Brookfield, Connecticut school system.^"* A level of 45,000 structures asbestos per square centimeters (s/cm^) was derived as the benchmark. This is remarkably high considering the universally accepted level of 1000 s/cm^ as low. (See Table 2.)

As discussed later, the Brookfield School System has roundly rejected EPA Region Ts unsafe level of 45,000 s cm asbestos dust, and has instead chosen a tentative cleanup level of 5000 s/cm^ for the schools to be occupied by its children.

Description of Region 2's risk assessment for settled asbestos dust: Use of a “K-factor” to back-calculate dust levels from background air levels

EPA Region 1 calculated its benchmark by first assigning a level for background ambient outside air. Then, it used a sliidy ' which found different ratios between the amount of dust on surfaces with the amount of asbestos in the air, depending on the activities going on in a room that would stir up dusts. The ratios of dust levels to air levels are called “K-factors.”

For its calculations. Region 1 assigned a false value of 0.045 structures per milliliter (s/mL) as the supposed background ambient outside air level. Then, then chose an incorrect K-factor of 0.000001 (which is the same as 10"^ if expressed as an exponential) as the ratio between air levels and dusts. The result was 45,000 structures per square centimeter (s/cm^) dust on surfaces, using the following formula.

Benchmark for x K-Factor [K-Factor Air Level, structures per milliliter asbestos in expressed (s/mL) Dust, structures as per square exponential

45,000 X 0.000001 [10 (-6)] 0.045 This is the level This is the K-factor, or multiplier, This is the alleged background outdoor air derived from the chosen by Region 1 level put into the formula by Region 1. This formula by Region 1 value is the one highest outlier measurement found in an early 1983 study.

- 12 -

CITY_21MC100_0 11992228

NYC-WTC_000433491

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000433491Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →