Asbestos Data
Based on the results that were received, it appears that eleven wipe samples and sixteen
microvacuum samples were collected by Ambient Group Inc. and analyzed by EMSL
Analytical Inc. for asbestos. An additional wipe sample and two microvacuum samples
were submitted as blanks. A summary of the results is presented below.
Location Matrix Sample Average Maximum
Size Concentration Concentration
(s/cm’l (s/cm^)
All locations Wipe II 4,327,650
Below floor Wipe 1 11,681
Wall Tracking Wipe 9 726,108 4,327,650
Below Light Wipe 1 8,652
Switch
Blank Wipe 1 2,164
All Locations Microvacuum 284,488 1,115,570
Below Floor Microvacuum 10 369,830 1,115,570
Wall Tracking Microvacuum 1 15,058
I-beam Microvacuum 2 7,636 8,038 (ND)
Column Microvacuum 1 8,038 (ND)
Pipe Shaft Microvacuum 1 71,592
Front Office Microvacuum 1 743,552
Blank Microvacuum 803
ND= asbestos not detected
The interpretation of these results is constrained by the scientific uncertainty regarding
the potential for the measured concentrations in settled dust to become airborne. There
are no standards currently available for assessing potential health consequences from
asbestos through the evaluation of wipe or microvacuum samples. A scientific peer
review panel (World Trade Center October 21- 22, 2002 Peer Review Meeting Notes.
Available at www.tera.org.) recently evaluated the technical soundness of estimating
airborne asbestos concentration as a function of asbestos concentration in settled dust for
the purpose of setting health-based benchmarks. The panel recommended against such an