I Taylor environmental grour inc. ELAP #10928

I Non-Friable Organically Bound Materials (NOBs)

I NOTE: The following procedure is an outline of NYS DOH Method 198.1 1 198.4 (NOB Section) which is to be followed for the analysis of bulk material samples that are determined to be non-friable organically bound material (e.g. floor tile, roof felt, mastic, etc.).

I 1) Preliminary Preparation: Remove all extraneous materials (wax, polish, mastic) prior to sample preparation. Mastic is considered a separate sample and must removed for independent analysis.

2) Organic Reduction: Shave off approximately 100-500 mg of material into a tared crucible and weigh. Place in muffle furnace at 480° Celsius until mass stabilizes (1 to 12 hours). Cool in a dessicator, re-weigh and calculate percent organic loss.

I 3) Acid Digestion: Grind residue in crucible with 0.5 ml of 0.1 pm - filtered deionized water and add 2 to 5 ml of concentrated HCl. After 15 minutes, pour solution into filtration apparatus loaded with a tared 0.4 pm polycarbonate filter, rinse crucible twice with deionized water, and apply vacuum. Rinse sides of filtration I apparatus with deionized water, transfer filter and residue to a tared petri dish, and allow filterZresidue to dry to stable mass. Weigh filter/residue and calculate percent carbonate loss.

NOTE: At this stage, if the residue mass is less than 1 % of the subsample's original mass, analysis is terminated and the sample is reported as non-asbestos containing material.

I 4) Sample Analysis (Identification): A minimum of four subsamples fi'om each filter are mounted and analyzed using procedures outlined in the Appendix to this Report titled "Bulk Material Sample Collection & Analysis Methodology."

I 5) Sample Analysis (Quantification): Quantification of positively identified asbestos fibers is achieved by comparing each slide preparation to verified standards. The amount of asbestos is then calculated as follows:

% asbestos = PAM x AOS OM

I PAM = mass of residue after furnace and acid treatments (mg) OM = mass of original subsample (mg) AOS = mean percentage of asbestos in final slide preparations.

I I I 130 JERICHO TPKE., FLORAL PARK, NY 11001 ■ PHONE (516) 358-2955 ■ FAX (516) 358-1780

CONFIDENTIAL, CITY_21MC100_013252308 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000432889

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000432889Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →