NYC 9/11 Public Portal Document
New York City School Construction Authority s Contract#: C000018706
SCA Project Manager: Hamid Savoj Project #: M477-15638, LLW# 29882
analysis and report preparation is also provided. This information is documented as follows;
1. Name and Address
2. Category of Accreditation
3. Date and Certificate of Accreditation (including the sponsor of the training course and the date and
location)
4. State of Accreditation and Accreditation Number
5. Name, Address, Accreditation and Certification of Each Analytical Laboratory Used
Poiarized Light Microscopy
Bulk samples collected for polarized light microscopy analysis are analyzed at Taylor Environmental Group's
in-house AIHA, NVLAP and ELAP accredited optical microscopy laboratory. Upon receipt of test items at the
laboratory, the Taylor Environmental Group Chain of Custody and Request for Analysis documents is
generated for all test item batches. If the test items have been collected by Taylor field staff then a Chain of
Custody document will have already been generated along with the Request for Analysis and the Daily
Monitoring documents.
Upon receipt of test items the Chain of Custody shall have the following information recorded:
1. Client Name
2. Project Location
3. Analyst & Method of Analysis
4. Number of Test Items in the Batch
5. List of Client Test Item Identification Numbers
6. Relevant Comments
7. STAT (Priority) Yes or No
8. Sampler's Signature (if possible) and Date
9. Carrier's Signature (if applicable) and Date
During the log-in procedure the Chain of Custody document is signed and dated by the log-in clerk. The
Chain of Custody document remains with the appropriate batch of test items through preparation and
analysis at which times it will be continually updated by all personnel who perform any action on the test
items.
Upon receipt of test items, the appropriate Taylor Environmental Group Inc. Request for Analysis document
is initiated if not already done by a Taylor field technician. All Request for Analysis documents have the
following information recorded:
1. Client Name and Address
2. Project Location
3. Date Received
4. Client Test Item Identification Numbers
5. Type of Analysis (if not already stated by document)
6. Origin of Test Item (if applicable)
7. Test Item Volume (if applicable)
During the log-in process the corresponding laboratory numbei-s shall be added to this document. At the
completion of sample log-in the pink copy of the Request for Analysis is removed and remains with the test
items.
At the completion of analysis of the test items the corresponding analytical results are transferred to the
yellow and white copies of the document. The analyst initials and dates this document in the appropriate
spaces provided.
The Request for Analysis is then signed and dated by the Laboratory Director for approval.
TAYLOR ENVIRONMENTAL GROUP, INC., 130A JERICHO TURNPIKE, FLORAL PARK, NY 11001
CONFIDENTIAL, CITY_21MC100_003471884
SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008
NYC-WTC_000432400
OCR can misread numbers and units. Confirm readings against the page image before using them.