NYC-WTC_000363060
Interim final report noting organizations involved and plan for third-party review.
44 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗EPA NYC Region 2 WTC response document, City data file.
NYC-WTC_000431857–000432027OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Field Observations ofEquipment Used Upright vacuums are designed for use on horizontal surfaces such as floors. These use rotating devices to collect dust, and do not provide direct suction force. Brush attachments were used on the horizontal surfaces that could be reached. The hose attachments were limited according to their length and hose type. Plastic hose was not as resilient as rubber or cloth-covered hose. Attachments such as the crevice tools were used with ease because of their small profile. These were made of plastic; therefore, they were not a concern around potential electrical sources. The vacuums were noisy in the areas being cleaned due to the unfurnished state of the units, and accordingly, the enhanced acoustics.
Shop vacuums are designed to provide easy unload of bulk debris. This type of vacuum typically provides a suction head lift of 48-51 inches of water. The shop vacuums were easy to maneuver even when pulled by the hose. They were also noisy in the unfurnished rooms. The hoses and attachments were larger in diameter than those of the upright vacuums. Crevice tools were larger than some spots to be cleaned. Cartridges loaded quickly with the fine dust being suctioned. Use of tube extensions and extra hose lengths facilitated the cleaning of vertical walls and ceilings. The cartridge filters required vacuuming to be cleaned of caked dust. Once this was completed, the suction increased dramatically.
Commercial quality vacuums are designed for heavy use. This type of vacuum typically provides a suction head lift of 82-93 inches of water. Certain accessories were specially designed for specific applications and required some understanding of their operational adjustments. The added instrumentation facilitated monitoring the operation of the equipment. Fine dust clogged the primary filter cloth easily when used in extreme conditions; however, the HEPA filter when checked visually appeared free of dust. Only the cloth filter required vacuuming. The Nilfisk™ vacuum has a duel motor drive, providing an intense suction allowing for better lift of trapped material than that obtained by off-the-shelf equipment. Each Nilfisk™ vacuum arrived with a 20 amp rated plug that did not conform to the receptacles in the building. The appropriate plug ends were procured and installed. At 92.6 pounds, the vacuum can be handled by one person who maneuvers it in a manner similar to the maneuver of a shopping cart. However, two people are required to ascend stairs with the vacuum.
Wet vacuums are designed to clean horizontal porous surfaces with soap and water (shampoo). The wet vacuums used in the study were an upright model, providing a suction head lift of 103 inches of water. This vacuum was easy for one person to use. The vacuum required hot water to work properly. The hot water had to be hand carried to the site in five-gallon buckets because hot water was not available. The vacuum could spray water or soap individually or both soap and water at the same time. It uniformly sprayed soap and water on the carpet. The soap and water was allowed to penetrate the carpet, and was then suctioned off of the carpet. This spraying capability facilitated the removal of dirt, dust, and debris from the surface.
Use of Swiffcr brand cloths was discontinued quickly because of the small coverage area provided. The cloth quickly loaded with dust and dried out. It then streaked the surfaces being cleaned. Both wet and dry types of Swiffer® cloths were used with the same result. Windex® brand cleaner and water was used as a replacement for the Swiffer® cloth.
Use of water without soap on horizontal surfaces resulted in smearing and re-deposit of the dirt. 15
CITY_21MC100_011132894
NYC-WTC_000431875
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000363060
Interim final report noting organizations involved and plan for third-party review.
44 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000195194
Document excerpt acknowledging contributors and outlining the collaborative scope of an EPA environmental protection study regarding the World Trade Center site.
45 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145695
Form documenting the tracking and handling of environmental samples collected by the Department of Environmental Protection.
45 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000276652
Table of contents for contaminants of [name] report and building sections.
32 shared non-person entities · 1 shared topics · similarity 0.990
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145027
Notice from NYC Law Department instructing staff to preserve World Trade Center documents for potential legal actions.
28 shared non-person entities · 1 shared topics · similarity 0.970
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155174
Chain of custody documentation for cleanup and monitoring samples at 114 Liberty distributed among project team members.
12 shared non-person entities · 1 shared topics · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000162938
Correspondence regarding monitoring activities and documentation for the asbestos cleanup at 114 Liberty Street in early 2003.
12 shared non-person entities · 1 shared topics · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000138897
Internal DEP coordination regarding comments on 114 Liberty procedures and preparation of a response.
12 shared non-person entities · 1 shared topics · similarity 0.964
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000243565
EIA report for Law Department project at 100 Church Street by TRC.
17 shared non-person entities · similarity 0.963
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000243703
Environmental assessment prepared for NYC Law Department by TRC Engineers, April 8, 2002.
17 shared non-person entities · similarity 0.962
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000155286
Formal letter criticizing the EPA and DEP for alleged failures in cleaning asbestos and silica from 114 Liberty Street.
13 shared non-person entities · similarity 0.962
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000176247
Comprehensive environmental assessment report prepared by TRC Engineers for the New York City Law Department.
17 shared non-person entities · similarity 0.962
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000145695
Form documenting the tracking and handling of environmental samples collected by the Department of Environmental Protection.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000363060
Interim final report noting organizations involved and plan for third-party review.
Similarity score 0.991 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000195194
Document excerpt acknowledging contributors and outlining the collaborative scope of an EPA environmental protection study regarding the World Trade Center site.
Similarity score 0.990 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000276652
Table of contents for contaminants of [name] report and building sections.
Similarity score 0.984 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000276652
Table of contents for contaminants of [name] report and building sections.
Similarity score 0.956 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000276652
Table of contents for contaminants of [name] report and building sections.
Similarity score 0.952 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000195194
Document excerpt acknowledging contributors and outlining the collaborative scope of an EPA environmental protection study regarding the World Trade Center site.
Similar indexed content
NYC-WTC_000363060
Interim final report noting organizations involved and plan for third-party review.
Similar indexed content
NYC-WTC_000145695
Form documenting the tracking and handling of environmental samples collected by the Department of Environmental Protection.
Similar indexed content
NYC-WTC_000276652
Table of contents for contaminants of [name] report and building sections.
Similar indexed content
NYC-WTC_000145027
Notice from NYC Law Department instructing staff to preserve World Trade Center documents for potential legal actions.
Similar indexed content