Asbestos fiber analysis report, Trinity Pl.

Machine-extracted title · confidence 42%

TEM asbestos fiber analysis performed for SCA Trinity Place project.

NYC-WTC_000430530–000430538
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

’ 208 Stonehinge Lane EMSL Analytical, Inc. Carle Place, NY 11514 Phone: (516) 997-7251 Fax: (516) 997-7528 EMSL Attn.: Taylor Environmental Group, Inc. Friday, February 22,2002 Floral Park Corporate Center 130-A Jericho Tpke. Ref Number: LI023032 Floral Park, NY 11001

Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed by EPA 40 CFR Part 763 Final Rule (AHERA)

I Project: SCA100 TRINITY PL.

#STRUCTURES Analytical Volume Asbestos ?■ 0..^ii - Non- Area Analyzed Sensitivity Asbestos Concentration Sample ID (liters) Type(s) < 5g 5g Asbestos (mm’) (S/cc) (S/mm*) (S/cc)

F-01 1805.00 None Detected 0 oTsoa 0.0042 <19.69 <0.0042

I F-02 1805.00 None Detected 0 0.0508 0.0042 <19.69 <0.0042

F-03 1805.00 None Detected 0 0.0508 0.0042 <19.69 <0.0042

F-04 1853.00 None Detected 0 0.0508 0.0041 <19.69 <0.0041

F-05 1805.00 None Detected 0 0.0508 0.0042 <19.69 <0.0042

F-06 1853.00 None Detected 0 0.0508 0.0041 <19.69 <0.0041

Earl Tracey Analyst Approved Signatory Disclaimers: This laboratory is not responsible for data reported in structures/cc. which is dependent on volume collected by non-laboratory personnel. This laboratory Is only responsible for data reported in structures/mm’. This report may not be reproduced, except in full, without written approval by EMSL. This report must not be used to claim product endorsement by NVLAP or any agency of the U.S. Government. This report relates only to the samples reported above. Quality control data (including 95% confidence limits and laboratory and analysts' accuracy and precision) is available upon request. J

fnr NVI AP PI M/TPM

CITY_21MC100_003114356

NYC-WTC_000430530

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000430530Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Asbestos TEM Analysis, PS 150

NYC-WTC_000322955

TEM asbestos analysis for PS 150 project; volume and asbestos presence noted.

Similar indexed content

Compare copies and versions →