ATC ASSOCIATES, INC 104 E 25th Street, 10th Floor New York, NY 10010 Tel. 212-353-8280 Fax 212-353-8306

REPORT DATE: 08-23-02

CLIENT: Taylor Environmental Group, Inc.

PROJECT NAME: SCA/Stuyvesant HS 10 th Floor

PROJECT NUMBER: M477-15217/29881

SAMPLED BY: Client

SAMPLE DATE 08-23-02 DATE RECEIVED: 08-23-02 DATE ANALYZED: 08-23-02

SAMPLE MEDIA: Air Samples ANALYSIS REQUIRED: Method NIOSH 7082

ANALYSIS RESULTS

SAMPLE BATCH SAMPLE DESCRIPTION LEAD DETECTION ID NO. CONCENTRATION LIMIT (Pg/ni’) (ng/m’)

10-Ll 21412 10th Floor Corridor Adj. To Rm 1037 <1,5 1.5

10-L2 21412 10th Floor Corridor Adj. To Rm 1010 <1.5 1.5

10-L3 21412 10th Floor Corridor Adj. To Staircase E <1.5 1.5

FBI 21412 Field Blank <1-5 ug 1-5 ng FB2 21412 Field Blank <1-5 ng 1-5 ng

NOTE 1: THE REPORTING LIMIT (RL) IS 3.0 ng NOTE 2; At the present time there arc no regulatory levels or requirements for indoor airborne lead in area samples. However. OSHA has established an action level of 30 ng/m’ and a permissible exposure level (PEL) of 50 ng/m’ for personal samples. NOTE 3: Blank units are in pg

CITY_21MC100_003114277

NYC-WTC_000430512

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000430512Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →