Asbestos TEM analysis, Stuyvesant HS

Machine-extracted title · confidence 25%

TEM asbestos analysis conducted for NYC SCA project at Stuyvesant High School, received Aug 21, 2002.

NYC-WTC_000430484
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

E^VISL Analytical, Inc. 307 West 38th Street, New York, NY 10018 EMSL Phone; 212 290-0051 Fax: 2122900058 Email: [email protected]

Attn: Taylor Environmental Group, Inc. Customer ID: TAYL50 Floral Park Corporate Center Customer PO: 130 Jericho Tpke. Floral Park, NY 11001 Received: 08/21/02 3:27 PM Fax: (516) 358-1780 Phone: 516-358-2955 EMSL Order: 030211565 Project: #IVI477-15217/29881 1SCAI Stuyvessant H.S. I Library EMSL Project ID: (Tent) Analysis Date: 8/21/02

Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed by EPA 40 CFR Part 763 Final Rule (AHERA) Analytical Asbestos # Structures Area iVon Asbestos Sensitivity Concentration Sample Volume Analyzed Asb Type(s) iO.S/i<5 S/j (S/cc) (S/mm‘) (S/cc) r^oi 1305.00 0.0625 0 None Detected 0.0047 <16.00 <0.0047 030211565-0001

T-02 1305.00 0.0625 0 None Detected 0.0047 <16.00 <0.0047 030211565-0002

T-03 1305.00 0.0625 0 None Detected 0.0047 <16.00 <0.0047 030211565-0003

T-04 1305.00 0.0625 0 None Detected 0.0047 <16.00 <0.0047 1^1^565-0^ 1305.00 0.0625 0 None Detected 0.0047 <16.00 <0.0047 030211565-0005

Analyst(s) Jose Arriaga (5) laboratory Manager V or other approved signatory

, Disclaimers: The laboratory is not responsible for data reported in structures/cc, which is dependent on volume collected by non-laboralory personnel. This lab is only responsible for I data reported in structures/mm', this report may not be reproduced, except in full, without written approval by EMSL. This report must not ba used to claim product endorsement by NVLAP or any agency of the U.S. Governmenl. This report relates only to ths samples reported above. Quality control data (Including 95% confidence limits and laboratory and analysts' accuracy end precision) is avaiiabte upon request JI Accrelited for NVLAP PLMfTEM #101048-9, NY State ELAP #11506

w iHERA-1 1

CITY_21MC100_001194398 NYC-WTC_000430484

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000430484Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →