NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Lead analysis, WTC site air, 9/27/01

Machine-extracted title · confidence 25%

Analytical results for air lead; Lab Batch 0109L2001; WTC Greenwich.

NYC-WTC_000429791
Page image
Scanned page image, NYC-WTC_000429791
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

JLC ENVIRONMENTAL CONSULTANTS, INC. 200 Park Avenue South, Suite 1001, New York. New York 10003 Phone; (212) 420-8119 Fax (212) 420-6092 P. T. & L Environmental Services Project No.: 01-2083010 ^Kette Drive ELAP Lab Code: 11029 Analyte; LEAD NIOSH and AIHA Lab Code: 100273 Date Collected; 972S'01 Paramus. NJ 07652 NVLAP Lab Code: 101953 Dale Received; 9«aoi Date Analyzed: 9Z27A31 Site; WTC #5, 6 & 7 - Greenwich Lab Batch#; 0109L2001

SUMMARY OF ANALYTICAL RESULTS - AIR

Sample # Lab# Description/ Location Volume (liter) Results (ug/m3) Client's Sample #

1 Inside the Trailer 960 9.7 17124 56504 2 Sign-in/ out/ Trailer 780 21.0 17125 56505 3 Comer of Murray & Greenwich 780 13.8 17126 56507 ^127 FIELD BLANK <4/ Filter

105 5 FIELD BLANK <4/ Filter 17128 106

Sample Analysis bv? Atofnis Absorption Sped/ometry (AAS) with an air^acetyiena burner head and background correction (AAS-F!arne).

Method of Sample Preparation and Analysis Collected By. Charies Colbert AH Samples were prepared and analyzed in accordance with NIOSH Method 7082, February IS. 1984, Analyzed By Tamara MetelWna

Gulam Machhiwela Laboratory Director

lum Oectection Limit = <4.0 ug/m3 OSHA Permissible Exposure Limit (PEL) for General Industry Is 50 ug/m3. 0e.Q03977 DISCLAIMER; JLC Environmental Consultants, Inc. did not collect the analyzed samples and thus accepts no liabilily with regard to their collection and/or maintenance. JLC reties on the client for all sample information prior to delivery at JLC. Page 1 of 1

CITY_21MC100_006788259

NYC-WTC_000429791

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000429791Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000220262

A summary of analytical results for lead air samples collected from World Trade Center sites 5, 6, and 7 in September 2001.

Similar indexed content

Lead air analysis results, WTC 5, 6 & 7, Sep

NYC-WTC_000220315

Analytical report from JLC Environmental Consultants providing lead concentration results for air samples taken at World Trade Center sites.

Similar indexed content

Compare copies and versions →