TEM Air Analysis, EMSL/RCME, Thames & Greenwich

Machine-extracted title · confidence 36%

Laboratory log of TEM air analysis samples collected 1/21–1/26/2006 at multiple street locations.

NYC-WTC_000428510–000428535
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

I Airtek Field Sample No. [Sampling Location [Real-time Readings Date |

GS-012006-EBAM10-1 # 1 - 100 Trinity roof 1/20/2006 GS-012006-EBAM10-2 # 2 - Thames St. 1/20/2006 GS-012006-EBAI\/l10-3 # 3 - Greenwich St. 1/20/2006 GS-012006-TEOM10-1 # 1 - 100 Trinity roof 1/20/2006 GS-012106-EBAM10-1 # 1 - 100 Trinity roof 1/21/2006 GS-012106-EBAM10-2 # 2 - Thames St. 1/21/2006 GS-012106-EBAM10-3 # 3 - Greenwich St. 1/21/2006 GS-012106-TEOM10-1 # 1 - 100 Trinity roof 1/21/2006 GS-012206-EBAM10-1 # 1 - 100 Trinity roof 1/22/2006 GS-012206-EBAM10-2 # 2 - Thames St. 1/22/2006 GS-012206-EBAI\/l10-3 # 3 - Greenwich St. 1/22/2006 GS-012206-TEOM10-1 # 1 - 100 Trinity roof 1/22/2006 GS-012306-EBAM10-1 # 1 - 100 Trinity roof 1/23/2006 GS-012306-EBAM10-2 # 2 - Thames St. 1/23/2006 GS-012306-EBAI\/l10-3 # 3 - Greenwich St. 1/23/2006 GS-012306-TEOM10-1 # 1 - 100 Trinity roof 1/23/2006 GS-012406-EBAM10-1 # 1 - 100 Trinity roof 1/24/2006 GS-012406-EBAM10-2 # 2 - Thames St. 1/24/2006 GS-012406-EBAI\/l10-3 # 3 - Greenwich St. 1/24/2006 GS-012406-TEOM10-1 # 1 - 100 Trinity roof 1/24/2006 GS-012506-EBAM10-1 # 1 - 100 Trinity roof 1/25/2006 GS-012506-EBAM10-2 # 2 - Thames St. 1/25/2006 GS-012506-EBAI\/l10-3 # 3 - Greenwich St. 1/25/2006 GS-012506-TEOM10-1 # 1 - 100 Trinity roof 1/25/2006 GS-012606-EBAM10-1 # 1 - 100 Trinity roof 1/26/2006 GS-012606-EBAI\/l10-2 # 2 - Thames St. 1/26/2006 GS-012606-EBAM10-3 # 3 - Greenwich St. 1/26/2006 GS-012606-TEOM10-1 # 1 - 100 Trinity roof 1/26/2006

Note 1: TEOM failed to re-start after routine maintenance operation on 1/20/06. Data for day is partial

Note 2: TEOM was dismantled on 1/21/06 for rotation from Thames Station to Greenwich Station. No s

Note 3: TEOM failed to datalog 1/23 and am of 1/24. Function corrected 1/24. 1/24 data is partial. No w

CITY_DEP_WORBY_CANNATA_SUBP_000115420

NYC-WTC_000428517

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000428517Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000428595

TEM air analysis result set for Thames/Greenwich streets; February 2006.

Similar indexed content

NYC-WTC_000428942

Laboratory results for air/soil samples at multiple sites including Thames and Greenwich Streets, dated Dec 2005.

Similar indexed content

Compare copies and versions →