NYC 9/11 Public Portal Document
Part V - Quality Assurance Project Plan
133-135 Greenwich Street/21-23 Thames Street
Airtek Project 05-0701 - September 29, 2005
laboratory will provide individually labeled containers that will be used to
transport the sample cartridges to the field location and back to the laboratory for
analysis.
• 0-100” Magnehelic Gage.
• White Cotton Gloves - For handling the filters and cartridges.
• Ice Chests - To hold samples at 4°C during shipment to the analytical laboratory.
10.2.6 Polychlorinated Biphenyls (PCBs)
Ambient air samples will be collected using a low-volume SKC Leland Legacy
personal sampling pump equipped with a glass cylinder containing a polyurethane
sorbent (i.e., PUF plug) for the collection of gas and particulate phase PCBs. Samples
will be collected at a flow rate of five liters per minute (5 1pm) with a sampling period of
approximately 24 hours for a resulting total air volume of approximately 7.2 cubic meters
(7.2 ms). The PUF (Polyurethane Foam) sampler is an air sampling system designed to
trap airborne organic vapors. The PUF sampler is equipped with a low-volume pump.
This feature is designed to permit the motor to operate at low sampling flow rates for
extended periods without motor failure from overheating. The sampling cartridge is
constructed of borosilicate glass, is filled with the PUF plug, and is connected to the
sampling pump by way of flexible tubing. Pump flow rates of each personal sampling
pump, with a representative sampler in line, will be measured before and after sample
collection. The pump will be run for 10 minutes prior to checking the flow rate. A
suitable rotameter (or bubble meter) will be connected to the filter inlet, the flow screw
adjusted to the desired sampling value, and the flow rate observed on the rotameter (or
bubble meter) will be verified as constant for a minimum of 20 seconds. Flow rates will
be recorded on Field Sampling Data Sheets or an equivalent field logbook. To initiate
sample collection, the aluminum foil is removed from the pre-cleaned cartridge assembly
(foil returned to the jar for later use) and the cartridge is attached to the pump
with flexible tubing. The sampling assembly is positioned with the intake downward or in
a horizontal position. The samplers are fastened to a location (i.e., on a tripod) near
the individual’s breathing zone at least 30 meters from any obstacle from air flow with
the PUF intake and at least 1 to 2 meters above ground level. After the PUF cartridge is
correctly inserted and positioned, the power switch is turned on, the elapsed time meter is
activated, sampling begins, and the start time is recorded on the Field Data Sheet or
equivalent field logbook. At the conclusion of each sampling period, the power switch is
turned off, stop time recorded, the PUF cartridge is removed from the pump and wrapped
with its original aluminum foil, the Teflon® end caps are replaced on the cartridge, and it
is placed back into its original sealed and labeled container, placed in an ice chest under
ice (< 4°C), and transported to the analytical laboratory for processing. Equipment and
supplies utilized with this sampling approach are as follows:
• Low-Volume, Continuous Flow Personal Sampling Pump - SKC Leland Legacy
Personal Monitor and Sampling Pump (or equivalent): 5 to 15 1pm.
• Battery Pack - Rechargeable lithium-ion battery pack (or equivalent) compatible
with the personal sampling pump.
49
CITY_DEP_WORBY_CANNATA_SUBP_0001 01700
NYC-WTC_000427948
OCR can misread numbers and units. Confirm readings against the page image before using them.