Part V - Quality Assurance Project Plan
133-135 Greenwich Street/21-23 Thames Street
Airtek Project 05-0701 - September 29, 2005
8.0 QUALITY OBJECTIVES AND CRITERIA FOR MEASUREMENT DATA
This section provides an overview of the environmental decisions that need to be made
and the level of data quality needed to ensure that these decisions are based on sound
scientific data.
8.1 Project Quality Objectives
As discussed in Section 6.2, the principal objective of the air monitoring program is to
monitor air quality in the vicinity of 133-135 Greenwich Street and 21-23 Thames Street
during the deconstruction of the building on that property. This objective will be satisfied
by the sampling and analysis program outlined in Tables 7-la, 7-lb, 7-lc, 7-2, and 7-3.
These tables outline the data needs by type, quantity, and quality. The type of data needed
to meet the project quality objectives (PQOs) includes the required contaminants of
concern, concentration levels, media to be sampled, analysis type, and appropriate
sampling techniques. These are detailed on Tables 7-la through 7-lc, 7-2, 7-3, and 8-1
and in Section 10.0. The quantity of data needed to meet the PQOs includes the
number of samples for each analytical parameter of each media and a definition of the
project boundaries. The first of these items is detailed on Tables 7-la through 7-lc. The
second of these items is dictated by the Ambient Air Monitoring Program for the 133-135
Greenwich Street and 21-23 Thames Street Deconstruction Project, September 2005. The
quality of data needed to achieve the PQOs includes the necessary data quality indicators
(precision, accuracy, representativeness, comparability, completeness, selectivity, and
sensitivity) required of each analytical parameter used for each media sampled. The
limits set on each of these items are referred to as measurement performance criteria and
define the quality of data generated. All measurement performance criteria have been
established for each parameter in order to ensure the data are sound, highly defensible,
and with quantitation limits significantly below project action levels. The type, quantity,
and quality of data needed to achieve the objectives listed above were predetermined. The
COPCs are outlined in Table 8-1 and include the quantitation limits and associated
project action levels for each contaminant of concern. This table has been completed for
each parameter. In general, the proposed analytical methodologies will be able to achieve
the PQOs. That is, the analytical methodologies are generally capable of detecting the
target analytes well below the applicable action limit. These methods provide data of
known quality and can be used for the objectives of this program. However, in order to
ensure that the analytical methodologies are capable of achieving the data quality
objectives, measurement performance criteria have been set for the analytical
measurements in terms of accuracy, precision, representativeness, completeness,
sensitivity, selectivity, and comparability.
33
CITY_DEP_WORBY_CANNATA_SUBP_0001 01684
NYC-WTC_000427932