Part V - Quality Assurance Project Plan
133-135 Greenwich Street/21-23 Thames Street
Airtek Project 05-0701 - September 29, 2005
any of the individual sample results exceed an USEPA Site Specific Trigger Level,
then notification must be made to the USEPA Region 2, NYCDEP and NYSDOL
as well as The Greenwich Street Project, LLC. Work will be reinitiated once the
USEPA Region 2 has agreed (and NYSDOL during the Abatement Phase in the
case of asbestos exceedances) to the corrective action(s) proposed to prevent the
potential for exceedances in future work and such corrective actions have been
implemented. The only exception to the work stoppage requirement will be for
an exceedance of the USEPA Site Specific Trigger Level for PM2.5 at one of the off
site roof top locations. If the USEPA Site Specific Trigger level for PM2.5 is
exceeded at an off-site roof top location, regulator notifications as described above
will be made and an assessment, with the active involvement of the USEPA, will be
performed to determine if the exceedance was due to an off-site or regional
condition unrelated to 133-135 Greenwich Street and 21-23 Thames Street work.
If the assessment determines the exceedance to be associated with 133-135
Greenwich Street and 21-23 Thames Street, the exceedance will result in a stoppage
of work associated with the exceedance until an evaluation of emission controls
is performed and corrective action acceptable to USEPA is in place. The Greenwich
Street Project, LLC’s consultant will monitor PMio and PM2.5 at each station in the
network on a continuous basis. These data will be reviewed on a routine basis
during the course of each 24 hour monitoring period and used to alert The
Greenwich Street Project, LLC of any potential exceedances of 24 hour action
levels established for these parameters. Corrective actions will be taken as needed
during the course of the work when warranted from review of the continuous
monitoring data.