Part V - Quality Assurance Project Plan
133-135 Greenwich Streel/21-23 Thames Street
Airtek Project 05-0701 - Rev 1 - January 27, 2006
• The laboratory uses methylene chloride for the extraction solvent instead of
10% ether/hexane and therefore does not perform the precleaning extraction of
800 mL methylene chloride of the Soxhlet apparatus.
• The final extract is brought down to a volume of 0.5 mL in methylene chloride.
11. J.2.2 Dioxin Extraction by EPA Method T0-9A
• The laboratory uses toluene for the extraction solvent instead of 10% diethyl
ether/hexane.
72
CITY_DEP_WORBY_CANNATA_SUBP_000093260
NYC-WTC_000427028
OCR can misread numbers and units. Confirm readings against the page image before using them.
NYC-WTC_000427028Source: NYC Law Department, mirrored locally