inserting a pin through the hole near the display screen, the elapsed time indicator is reset
prior to sampling. At the end of the sampling period, the top cover and small end caps are
replaced. Samples are transported upright to the laboratory in a rigid container with
packing material to prevent jostling or damage. To avoid electrostatic forces from
causing fiber loss from the sampling filter, untreated polystyrene foam will not be used
for any of the shipping container materials. Collection of a site-specific dust sample will
be performed as discussed in Section 8.2.2. This sample needs to be double-bagged prior
to shipment to avoid any potential cross-contamination. Equipment and supplies utilized
with this sampling approach are as follows:
• Personal Monitor and Sampling Pump 0.5 to 3 1pm • Battery Pack - Nickel metal
hydride battery pack (or equivalent), fitted with a belt clip, compatible with the
personal sampling pump.
• Filters - Polyvinyl filter (or equivalent hydrophobic membrane filter) supported
by a cassette filter holder, S.O-pm pore size, suitable for connection with the
personal monitoring pump system.
• Cyclone - SKC Inc. aluminum cyclone (or equivalent) • Medium Flow Rotometer
- 0.4 to 4.0 1pm • High Flow Rotometer - 2.0 to 20.0 1pm • Forceps - Nylon, used
when handling the filters
10.2.5 Polychlorinated Dibenzodioxins (PCDDs) and Polychlorinated
Dibenzofurans (PCDFs)
Ambient air samples will be collected using a Tisch PUF (or performance equivalent)
high volume air sampling system equipped for the collection of semivolatile
PCDD/PCDF particulate matter on a 102-mm diameter microquartz fiber filter, as well as
a glass cylinder containing a polyurethane sorbent (i.e., PUF plug) for the collection
of gas phase PCDDs/PCDFs. At each site, one Tisch PUF sampler will be used to
collect PCDD/PCDF samples according to Method TO-9A. Samples will be collected at a
flow rate of 200 to 300 liters per minute (1pm) over a sampling period of approximately
24 hours for a resulting total air volume of approximately 288-432 cubic meters (288-432
ms). The PUF (Polyurethane Foam) sampler is a complete air sampling system designed
to simultaneously collect suspended airborne particulates as well as trap airborne organic
vapors. The PUF sampler is equipped with a bypass blower motor arranged with an
independent cooling fan. This feature permits the motor to operate at low sampling flow
rates for extended periods without motor failure from overheating. A dual chambered
aluminum sampling module contains both filtering systems. The upper chamber supports
the airborne particulate filter media in a circular filter holder. The lower chamber
encapsulates a glass cartridge, which contains the PUF for vapor entrapment. The voltage
variator adjustment screw alters the blower motor speed to achieve the desired flow rate.
Air flow rate is measured through the flow venturi utilizing a 0-100” Magnehelic
Gage. For each sample, the sampling start and end times and flow rates are recorded on
Field Sampling Data Sheets or an equivalent field logbook and used to calculate the
amount of ambient air sampled. At the conclusion of each sampling period, the sample is