NYC 9/11 Public Portal Document
Part V - Quality Assurance Project Plan
133-135 Greenwich Streel/21-23 Thames Street
Airtek Project 05-0701 - Rev 1 - January 27, 2006
mercury. The data produced from all analyses will be evaluated and used.
Based upon regulatory requirements for waste characterization, oneor more of the
following target parameters are included in the monitoring program:
Toxicity Characteristic Leaching Procedure (TCLP)
TCLP SVOCs
TCLP Pesticides
TCLP Herbicides
TCLP Metals
Ignitability
Corrosivity
Reactive Cyanide
Reactive Sulfide
PCBs
8.0 QUALITY OBJECTIVES AND CRITERIA FOR MEASUREMENT DATA
This section provides an oveiwiew of the environmental decisions that need to be made
and the level of data quality needed to ensure that these decisions are based on sound
scientific data.
8.1 Project Quality Objectives
As discussed in Section 6.2, the principal objective of the air monitoring program is to
monitor air quality in the vicinity of 133-135 Greenwich Street and 21-23 Thames Street
during the deconstruction of the building on that property. Waste characterization
objectives are also included in this QAPP. These objectives will be satisfied by the
sampling and analysis program outlined in Tables 7-la, 7-lb, 7-lc, 7-2, and 7-3. These
tables outline the data needs by type, quantity, and quality. The type of data needed to
meet the project quality objectives (PQOs) includes the required contaminants of
concern, concentration levels, media to be sampled, analysis type, and appropriate
sampling techniques. These are detailed on Tables 7-la through 7-lc, 7-2, 7-3, and 8-1
and in Section 10.0. The quantity of data needed to meet the PQOs includes the
number of samples for each analytical parameter of each media and a definition of the
project boundaries. The first of these items is detailed on Tables 7-la through 7-lc. The
second of these items is dictated by the Part II - Environmental Community Air
Monitoring Plan During Abatement and Demolition. The quality of data needed to
achieve the PQOs includes the necessary data quality indicators (precision, accuracy,
representativeness, comparability, completeness, selectivity, and sensitivity) required of
each analytical parameter used for each media sampled. The limits set on each of these
items are referred to as measurement performance criteria and define the quality of data
generated. All measurement performance criteria have been established for each
parameter in order to ensure the data are sound, highly defensible, and with quantitation
limits significantly below project action levels. The type, quantity, and quality of data
needed to achieve the objectives listed above were predetermined. The COPCs are
34
CITY_DEP_WORBY_CANNATA_SUBP_000093222
NYC-WTC_000426990
OCR can misread numbers and units. Confirm readings against the page image before using them.