NYC 9/11 Public Portal Document
Part V - Quality Assurance Project Plan
133-135 Greenwich Streel/21-23 Thames Street
Airtek Project 05-0701 - Rev 1 - January 27, 2006
guidelines:
• Evaluation of Metals Data for the CLP Program, January 1992, SOP HW-2,
Revision 11
• TCLP Data Validation, March 1993, SOP HW-7, Revision 3
• Validating Chlorinated Herbicides by Gas Chromatography, November 1994, SOP
HW-17, Revision 1.3
• Validating Semivolatile Organic Compounds by SW-846 Method 8270, June 2001,
SOP HW-22, Revision 2
• Validating Pesticide/PCB Compounds by SW-846 Method 8080A, May 1995, SOP
HW-23, Revision 0
• Validating PCB Compounds by SW-846 Method 8082, May 2002, SOP HW-23B,
Revision 1.0
• Validating Volatile Organic Compounds by SW-846 Method S260B, June 1999,
SOP HW-24, Revision 1”
All data from the Background Phase will be subjected to a limited validation, which
includes, at a minimum, a completeness check, an evaluation of chain-of-custody and
sample login documents, an overall evaluation of data and potential usability issues,
technical holding times, and QC sample results (blanks, surrogate spikes, MS/MSDs,
calibrations, matrix duplicates, and LCS, etc.). Following this, a limited validation
will be performed on a subset of the data. For the first two months of the program, the
validation will be performed on a weekly basis followed by a monthly basis
thereafter. Completeness checks will be administered on all data to determine
whether deliverables specified in the QAPP are present. The reviewer will
determine whether all required items are present and will request copies of missing
deliverables. Field notes will be reviewed in conjunction with the laboratory data to
allow for an overall assessment. Upon completion of the validation, a report will be
prepared summarizing the elements reviewed. Validated data will be used to generate
tables. Potential validation qualifiers are as follows:
U - Not detected at the specified quantitation/detection limit
UJ - Estimated nondetect
J - Estimated value
R - Unusable data point
N - Presumptively present
16.2 Data Usability
The purpose of this section is to indicate the methods by which it will be ensured that
the validated laboratory data collected for this investigation are consistent with the
project quality objectives established for the project, to ensure the quality of data was
sufficient for its intended use, and to identify trends, relationships, and anomalies in
the data. Conclusions based on the data, limitations on the use of the data, and the
determination if data gaps exist will be included in the Data Validation memoranda.
This will be performed on a per sample batch basis.
122
CITY_DEP_WORBY_CANNATA_SUBP_000093310
NYC-WTC_000427078
OCR can misread numbers and units. Confirm readings against the page image before using them.