Part V - Quality Assurance Project Plan
133-135 Greenwich Streel/21-23 Thames Street
Airtek Project 05-0701 - Rev 1 - January 27, 2006
Retune GCMSVOC01170
BFB Tuning Every 12 hours Method 8260B Criteria
Recalibrate system 0
GC/MS Initial cal. (5 stds) As needed CCC RSDs < 30%’ Rf for
Volatiles Every 12 hours Reran blank, rerun Revision 1.7
Method blank SPCCs >0.05, RSD Avg <
Every 12 hours 15% affected samples
Cont. calibration
All Acetone, MeCL < 25 ppb Reran cal chk and all
Surrogate stds.
CCCs < 25%D; SPCCs > 0.05 affected samples
Laboratory Once/20 samples
Within Laboratory Control Reran afftcccd samples
Control Once/20 samples
limits Reran LCS and all
MS/MSD ALL
affected samples
Internal Standards
-50% to+100% of 12 hr Cal. Reran MS/MSD and
affected samples
Reran affected samples
Recalibrate System GCPEST011799
Initial cal. (5 stds) As needed RSDs all <20%
GC Cont. caUbration Reran all affected Revision 1.1
Every 10 samples < 15 % Difference
Pesticides/ (midpoint) samples under good GCHERB011999
one per batch Not detected CCV
Herbicides method blank Revision 1.2
and PCBs All Within Lab control limits Reexlract, rerun
surrogate stds. GCPCB011799
Once per 20 Within lab control limits Re extract samples with
MS/MSD & LCS Revision 1.2
samples both surrogates out
Reextract or reanaly ze
affected samples where
LCS is out.
GCMSSVOC0117
DFTPP Tuning Every 12 hours SW846-8270c criteria Retune, rerun for
00
GC/MS Semi Initial cal. (5 stds) As needed CCCs <30%RSD, SPCCs > DFTPP criteria
Volatiles Revision 1.4
method blank 1/20 per matrix 0.05 Rf; RSD avg.< 15% Recalibrate
No tar gets found Re extract mblk
Cont. caUbration every 12 hours
CCCs @ <25%D; SPCCs> Rerun or recal/rerun all
Surrogate stds. ALL
0.05Rf afftected samples
Laboratory 1/20 per matrix
Within Lab control limits Re-extract
Control 1/20 per matrix
Within Lab control limits Reclibrate/ rerun all
MS/MSD ALL
samples
Internal Standards
-50 to +100% of 12 hour cal Reextract & rerun
chk std. Rerun affected samples,
dilute if matrix is issue
Hg120998
Initial cal. (5 stds) As needed 0.995 Corr. Coeff. Recalibrate system
Mercury/CV Revision 1.1
metliod blank Every 20 samples Not detected Reran affected samples
AA
Cont. calibration Every 10 samples +/- 20% Reran affected samples
Spike and Dup 1/20 samples Spike +/- 25%, Dup +/- 20% at Rerun spike/dup unless
levels >5x Reporting Limit proven matrix
Mfgs. Specs. interference
LCS 1/20 samples
Rerun all affected
samples
Recalibrate ICP sy stem ICP031195
Initial calibration As needed +/- 10%
ICP metals Reran affected samples Revision 1.2
Cont. cahbration Every 10 samples +/- 10%
Reran or qualify
Calibration blanks Every 10 samples Not detected (<1DL)
affected samples