Ambient Air Monitoring Program Section No. 10 Quality Assurance Project Plan Revision No.: 0 130 Liberty Street - NY, NY Date: September 7, 2005 Lower Manhattan Development Corporation Page 59 of 124

10.0 FIELD MONITORING REQUIREMENTS

10.1 Monitoring Process Design

Refer to Section 7.1.1 for the monitoring design of this project. This section discusses the areas being sampled, what is being tested, and how often.

10.1.1 Meteorological Data Collection

Potential sources of variability may be due to meteorological data. Due to the complex nature of wind movement in an around buildings in the urban setting of Lower Manhattan, monitoring of wind velocity and direction on a continuous basis is warranted. Data available from regional National Weather Stations (NWS) such as Newark Airport, LaGuardia and Kennedy Airports can be used to complement the localized data but it is likely NWS data may not always be representative of conditions in and around the 130 Liberty Street site. A meteorological station will be deployed in the immediate vicinity of the site. The actual station will initially be located at roof top level at the deconstruction site (130 Liberty Street).

Data from the roof top station will be logged continuously at the unit’s data logger and also transmitted via cellular modem to the street level computer station.

The meteorological monitoring component of the air sampling and monitoring program will consist of equipment (Met One) designed to continuously record wind speed, wind direction, and air temperature from a roof mount tower. Monitoring will be done from the roof of the building at 130 Liberty Street until deconstruction activities warrant its physical removal when the roof is removed or access is denied due to ongoing construction activities. The 130 Liberty Street roof­ mounted station will then be collocated with one of the off site rooftop air monitoring stations.

10.2 Monitoring Methods

The following sections provide a brief description of the sampling procedures to be employed for each parameter and a summary of the required equipment. Step-by-step operating procedures are included as Attachment C.

10.2.1 Metals (TSP Filters)

Total suspended particulate (TSP) samples to be analyzed for metals will be collected employing high-volume air sampling techniques in accordance with US EPA standard reference method 40 CFR Part 50 Appendix B, Reference Method for the Determination of Suspended Particulate Matter in the Atmosphere (High-Volume Method). Samples will be collected over an estimated twenty-four hour sampling period. During this period ambient air will be collected at a flow rate of approximately 1 m^/minute. Numbered, preweighed quartz fiber filters provided by the subcontracted laboratory will be placed in each sampling system prior to the start of each sampling event. The air sampler draws approximately 1200-1500 m^ through the filter during

CITY_DEP_WORBY_CANNATA_SUBP_000092820

NYC-WTC_000426880

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000426880Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000421972

QA plan for ambient air monitoring for the 130 Liberty Street deconstruction project, Sept 2005.

Similar indexed content

NYC-WTC_000423219

Quality assurance plan and project details for ambient air monitoring near 130 Liberty Street, Sep 2005.

Similar indexed content

NYC-WTC_000422676

QA plan for ambient air monitoring program for LMDC deconstruction at 130 Liberty Street.

Similar indexed content

NYC-WTC_000426556

Quality assurance plan for ambient air monitoring, 130 Liberty Street, Sept 2005.

Similar indexed content

NYC-WTC_000421711

Quality assurance plan for ambient air monitoring during LMDC project at 130 Liberty Street.

Similar indexed content

Compare copies and versions →