NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 133 pages

Environmental Community Air Monitoring Plan, Greenwich/Thames

Machine-extracted title · confidence 42%

Plan document for environmental community air monitoring at Greenwich/Thames sites, Sept 2005.

NYC-WTC_000426688–000426820
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Part V - Quality Assurance Project Plan 133-135 Greenwich Streel/21-23 Thames Street Airtek Project 05-0701 - Rev 1 - October 21, 2005

Chloroform ^A.O - 250 Chromium l35017^Sr^ 1,4-Dichlorobenzene 250- 12.500 1,2-Dichloroethane IqT"" 2,4-Dinitrotoluene ^0 13 250- 12.500 Endrin 10.02 40- 500 Heptachlor (and its epoxide) 'Eoos - 250 Lead 50 BWioolboo Lindane 04 .5 - 250 Mercury 1100 5,bob Methyl ethyl ketone 1200.0 .5 - 250 Nitrobenzene 20 A - 250 Silver 1510 135017,500 Trichloroethylene .5 - 250 2.4.6-Trichlorophenol 2.0 250- 12.500 Vinyl chloride ^Source: 55 FR 11862, Mar. 29, 1990, as amended at 55 FR 22684, June 1, 1990; 55 FR 26987, June 29, 1990; 58 FR 46049, Aug. 31, 1993 2 Source: “Guidance for Methods Development and Methods Validation for RCRA Program” (http://www.epa.gov/epaoswer/hazwaste/test/pdfs/methdev.pdf) ^Quantitation limit is greater than the calculated regulatory level. The quantitation limit therefore becomes the regulatory level. '‘If O-, m-, and p-Cresol concentrations cannot be differentiated, the total cresol (D026) concentration is used. The regulatory level of total cresol is 200 mg/l.

8.2 Measurement Performance Criteria The 133-135 Greenwich Street and 21-23 Thames Street Environmental Community Air Monitoring Program and Waste Management Plan are designed to produce data of the quality necessary to achieve PQOs and meet or exceed the minimum standard requirements for field and analytical methods. The overall QA objective is to develop and implement procedures for field sampling, chain-of-custody, laboratory analysis, and reporting which will provide results that are scientifically valid, and the levels of which are sufficient to meet PQOs. Specific procedures for sampling, chain of custody, laboratory and field instruments calibration, laboratory analysis, reporting of data, internal quality control, preventative maintenance of field and laboratory equipment, and coiTective action are described in other sections of this QAPP. The purpose of this section is to state the specific, required QA objectives for accuracy, precision, representativeness, completeness, sensitivity, selectivity, and comparability. Measurement performance criteria for precision, accuracy/bias, representativeness, completeness, sensitivity, quantitation limits, selectivity, and comparability have been established for each parameter and are summarized in Tables 8-2 through 8-10. These measures of performance are also referred to as Data Quality Indicators (DQIs) and are discussed in detail below.

37

CITY_DEP_WORBY_CANNATA_SUBP_000092316

NYC-WTC_000426724

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000426724Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000424189

Plan title and approval sheet for environmental air monitoring, Greenwich/Thames.

Similar indexed content

NYC-WTC_000423370

Plan document for environmental community air monitoring at Greenwich and Thames Street sites, Nov 2005.

Similar indexed content

NYC-WTC_000427582

CoC document for Greenwich/Thames Street air monitoring plan dated Nov 9, 2005.

Similar indexed content

NYC-WTC_000426214

Plan document outlining community air monitoring for Greenwich and Thames sites.

Similar indexed content

NYC-WTC_000427415

CoC document detailing plan for Environmental Community Air Monitoring at Greenwich Street sites.

Similar indexed content

Compare copies and versions →