Ambient Air Monitoring Program Section No. 10 Quality Assurance Project Plan Revision No.: 0 130 Liberty Street - NY, NY Date: September 7, 2005 Lower Manhattan Development Corporation Page 63 of 124

Immediately prior to collecting a sample, the sampler will be fastened to a location (i.e., on a tripod) near the individual’s breathing zone, the top cover of the filter cassette cowl extension (“open face”) will be removed and positioned “face down” in the sampler. The joint between the extender and monitor body will be wrapped with tape to hold the cassette securely in place and to provide a surface to identify the cassette. By inserting a pin through the hole near the display screen, the elapsed time indicator is reset prior to sampling.

At the end of the sampling period, the top cover and small end caps are replaced. Samples are transported upright to the laboratory in a rigid container with packing material to prevent jostling or damage. To avoid electrostatic forces from causing fiber loss from the sampling filter, untreated polystyrene foam will not be used for any of the shipping container materials.

Collection of a site-specific dust sample will be performed as discussed in Section 8.2.2. This sample needs to be double-bagged prior to shipment to avoid any potential cross-contamination.

Equipment and supplies utilized with this sampling approach are as follows:

• Personal Monitor and Sampling Pump 0.5 to 3 1pm

• Battery Pack - Nickel metal hydride battery pack (or equivalent), fitted with a belt clip, compatible with the personal sampling pump.

• Filters - Polyvinyl filter (or equivalent hydrophobic membrane filter) supported by a cassette filter holder, 5.0-pm pore size, suitable for connection with the personal monitoring pump system.

• Cyclone - SKC Inc. aluminum cyclone (or equivalent)

• Medium Flow Rotometer - 0.4 to 4.0 1pm

• High Flow Rotometer - 2.0 to 20.0 1pm

• Forceps - Nylon, used when handling the filters

10.2.5 Polychlorinated Dibenzodioxins (PCDDs) and Polychlorinated Dibenzofurans (PCDFs)

Ambient air samples will be collected using a General Metals Works (GMW) PS-1 (or performance equivalent) high volume air sampling system equipped for the collection of semivolatile PCDD/PCDF particulate matter on a 102-mm diameter microquartz fiber filter, as well as a glass cylinder containing a polyurethane sorbent (i.e., PUF plug) for the collection of gas phase PCDDs/PCDFs. At each site, one GMW PS-1 sampler will be used to collect PCDD/PCDF samples according to Method TO-9A. Samples will be collected at a flow rate of

CITY_DEP_WORBY_CANNATA_SUBP_000091993

NYC-WTC_000426619

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000426619Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000426821

QA plan reference for deconstruction ambient air monitoring, Sept 2005.

Similar indexed content

NYC-WTC_000421972

QA plan for ambient air monitoring for the 130 Liberty Street deconstruction project, Sept 2005.

Similar indexed content

NYC-WTC_000423219

Quality assurance plan and project details for ambient air monitoring near 130 Liberty Street, Sep 2005.

Similar indexed content

NYC-WTC_000422676

QA plan for ambient air monitoring program for LMDC deconstruction at 130 Liberty Street.

Similar indexed content

NYC-WTC_000421711

Quality assurance plan for ambient air monitoring during LMDC project at 130 Liberty Street.

Similar indexed content

Compare copies and versions →