Ambient Air Monitoring Program Section No. 8 Quality Assurance Project Plan Revision No.: 0 130 Liberty Street - NY, NY Date: September 7, 2005 Lower Manhattan Development Corporation Page 45 of 124

Precision is the agreement among a set of replicate measurements without consideration of the “true” or accurate value: i.e., variability between measurements of the same material for the same analyte. Precision is measured in a variety of ways including statistically, such as calculating variance or standard deviation. The results of the background phase will be used to monitor overall precision (field and laboratory) and will be included as Attachment B to the QAPP, when available.

Field Precision Ob jectives

Field precision is assessed through the collection and measurement of collocated samples (also called field duplicates) which consist of a second sample in addition to the original field sample. In general, field duplicates will be collected at a frequency of once per week per analytical parameter. Precision will be measured through the calculation of relative percent difference (RPD). The resulting information will be used to assess sample homogeneity, spatial variability at the site, sample collection reproducibility, and analytical variability. Field duplicate RPDs must be < 40. Field precision will be maintained by utilizing experienced/trained sampling crews and conducting field audits.

In addition, during the background phase of the program, the precision of the mercury sampling and analysis method will be tested. Ambient air samples will be collected at one location using a series of four iodated carbon traps prespiked (50 ng/trap) with mercury. These samples will provide data on the precision of the method under actual field sampling conditions. Following the background phase, one field spike will be performed every other week, alternating with the field duplicates.

Laboratory Precision Objectives

Precision in the laboratory is assessed through the calculation of RPD for duplicate preparation and analyses of laboratory control samples, or replicate injections of samples. Laboratory precision measures both sample preparation and analysis reproducibility. Precision control limits and frequency of precision measurements are provided in Tables 8-2 through 8-9.

8.2.2 Accuracy

Accuracy is the closeness of agreement between an observed value and an accepted reference value. The difference between the observed value and the reference value includes components of both systematic error (bias) and random error.

CITY_DEP_WORBY_CANNATA_SUBP_000091975

NYC-WTC_000426601

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000426601Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000426821

QA plan reference for deconstruction ambient air monitoring, Sept 2005.

Similar indexed content

NYC-WTC_000421972

QA plan for ambient air monitoring for the 130 Liberty Street deconstruction project, Sept 2005.

Similar indexed content

NYC-WTC_000423219

Quality assurance plan and project details for ambient air monitoring near 130 Liberty Street, Sep 2005.

Similar indexed content

NYC-WTC_000422676

QA plan for ambient air monitoring program for LMDC deconstruction at 130 Liberty Street.

Similar indexed content

NYC-WTC_000421711

Quality assurance plan for ambient air monitoring during LMDC project at 130 Liberty Street.

Similar indexed content

Compare copies and versions →