Part V - Quality Assurance Project Plan 133-135 Greenwich Street/21-23 Thames Street Airtek Project 05-0701 - November 4, 2005

performance and isomer specificity. S/N ratio must be > 10:1 for labeled standards and >5:1 for unlabeled standards. PAHs/GS/MS Initial calibration: Perform necessary prior to sample equipment analysis or maintenance and whenever indicated check calibration by continuing standards. calibration________ Initial calibration 70-130% of true Verification: value immediately after the initial calibration curve Continuing RRFs must be Calibration: prior to within ± 30% of analysis at actual calibration beginning of each mean RRFs: S/N 12-hour shift ratio must be >10:1 for labeled standards and > 2:5:1 for unlabeled standards. PCBs/GC/ECD Initial calibration: %RSD of CFs must Perform necessary prior to sample be <20 equipment analysis or maintenance and whenever indicated check calibration by continuing standards. calibration_______ Initial calibration 85-115% of true Verification: value immediately after the initial calibration curve Continuing CFs must be within Calibration: 15% of initial beginning of each calibration mean day, every 10 CFs samples, and at end of analytical sequence

97

CITY_DEP_WORBY_CANNATA_SUBP_000091569

NYC-WTC_000426444

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000426444Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000427716

CoC document for Greenwich/Thames Street air monitoring plan dated Nov 9, 2005.

Similar indexed content

NYC-WTC_000424323

Plan title and approval sheet for environmental air monitoring, Greenwich/Thames.

Similar indexed content

NYC-WTC_000423504

Plan document for environmental community air monitoring at Greenwich Street and 21-23 Thames Street, Nov 2005.

Similar indexed content

NYC-WTC_000444945

Plan and submittals for environmental community air monitoring at 133-135 Greenwich and 21-23 Thames.

Similar indexed content

NYC-WTC_000447434

Chain of custody plan for Greenwich Street/Thames Street site air monitoring.

Similar indexed content

Compare copies and versions →