RJ Lee Group, Inc. Laboratory Report (cont’d) RJ Lee Group Job No: ATH411066-220 RJ Lee Group, Inc. Building: 4 Albany Report Date: 1/29/2005

Concentration Date-Time Collected Filter Area Asbestos Analytical RJLG Sample Sample Start Area Volume Analyzed structures Sensitivity Number Type -Sub Location (mn?) (liter) (mn?) Chry Amph (S/mnf) (S/cc) Stop

5238497.HT Area 1/27/2005 - 15:15:00 (West) - Washington Street. 385 2260.00 0.17721 0 0 5.6 <0.001 1/27/2005 - 22:47:00 5.6 0661

5238498.HT Area 1/27/2005 - 15:07:00 (Northwest) - Albany Street West. 385 2285.00 0.17721 0 0 <5.6 <0.001 1/27/2005 - 22:44:00 "5.6 OSOT

5238505.HT Aiea 1/27/2005 - 17:52:00 (South) - AFD Exhaust. Carlise 385 2230.00 0.17721 0 0 <5.6 <0.001 1/28/2005 -01:18:00 Street Sidewalk. Bridge, position 5.6 0.00 f

Authorized Signature: Kimberly A. Allison, Manager - TEM Analysis

Notes: 1. Volumes provided by Deutsche Bank were used to calculate analytical results and sensitivities. 2. indicates results less than analytical sensitivity. “—” indicates that sample was not analyzed. 3. Sample(s) for this project were analyzed al our: Monroeville, PA (NVLAP #101208-0, NY ELAP #10844) facility. 4. If RJ Lee Group, Inc. did not collect the samples analyzed, the verifiability of the laboratory's results are limited to the reported values. 5. Abbreviations: N/A-Not Applicable, Chry-Chrysotilc Asbestos, Amph-Amphibolo Asbestos, S-Structurcs. 6. Samples will be held for 90 days and then disposed of per Federal regulations. 7. These results are submitted pursuant to RJ Lee Group’s current terms and conditions of sale, including the company’s standard warranty and limitation of liability provisions. No responsibility or liability is assumed for the manner in which these results are used or interpreted.

See Appendix A for fiber data. Page 2 of 3

CITY_DEP_WORBY_CANNATA_SUBP_000077930

NYC-WTC_000425056

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000425056Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000426027

Final TEM air analysis report dated 1/29/2005 for Building 4, RJ LeeGroup.

Similar indexed content

NYC-WTC_000425685

TEM air analysis final lab report for building 4, dated 2005.

Similar indexed content

NYC-WTC_000425922

Final TEM air analysis report for building 4, dated 8/1/2005.

Similar indexed content

Compare copies and versions →