Part V - Quality Assurance Project Plan 133-135 Greenwich Street/21-23 Thames Street Airtek Project 05-0701 - November 4, 2005

Mercury/CVAFS Initial Calibration: % RSD< 15 or r’ > Perform prior to sample 0.999; percent recovery necessary analysis of each standard in equipment curve 90-110% when maintenance calculated with curve and check with the exception of calibration the lowest standards concentration standard which must be 75- 125%____________ Initial Calibration 90-110% of true value Verification: immediately after initial calibration Continuing 90-110% of true value Calibration Verification: every 10 samples or every 12 hours, whichever is more frequent and at end of analytical sequence Dioxins & Initial Calibration: % RSD of RRFs must Perform Furans/HRGC/HRMS prior to sample be <10 for unlabeled necessary analysis; once standards; % RSD of equipment every 6 months of RRFs must be < 20 for maintenance whenever indicated labeled standards. S.N and check by continuing ratio must be > 10:1 for calibration calibration labeled standards and standards >5:1 for unlabeled standards.

Table 13-4a. Summary of Calibration Procedures for Fixed Laboratory Analyses Parameter Frequency of Acceptance Corrective Action Instrument (alibratioii (ritcria Continuing RRFs must be Calibration within ± 20% of Verification (BCS initial calibration 3): beginning and mean RRF for end of each 12 hour unlabeled standards shift or batch, and± 30% for whichever is smaller labeled standards; verify GC column

96

CITY_DEP_WORBY_CANNATA_SUBP_000058607

NYC-WTC_000423599

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000423599Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000424323

Plan title and approval sheet for environmental air monitoring, Greenwich/Thames.

Similar indexed content

NYC-WTC_000426348

Plan document outlining community air monitoring for Greenwich and Thames sites.

Similar indexed content

NYC-WTC_000427716

CoC document for Greenwich/Thames Street air monitoring plan dated Nov 9, 2005.

Similar indexed content

NYC-WTC_000447434

Chain of custody plan for Greenwich Street/Thames Street site air monitoring.

Similar indexed content

NYC-WTC_000444945

Plan and submittals for environmental community air monitoring at 133-135 Greenwich and 21-23 Thames.

Similar indexed content

Compare copies and versions →