Part V - Quality Assurance Project Plan 133-135 Greenwich Streel/21-23 Thames Street Airtek Project 05-0701 - November 4, 2005

Field/Trip 1/day No target Reclean, Accuracy/Bias- Blanks compounds > reanalyze, Contamination QL and/or qualify PUF Media 1/batch cleaned No target Reclean, Accuracy/Bias- Cleaning compounds > reanalyze, Contamination Verification QL and/or qualify Check Recovery Every sample, Signal: noise Reanalyze Accuracy/Bias Standards blank, QC ratio must be > and/or qualify 10:1 data. Data NA Field 80%; NA Data Completeness Laboratory Completeness Check 95% ° Includes the following compounds: ”C14-2,3,7,8-TCDD:1.6ng >’012-1.2,3,4,7-PeCDD:4ng >’Ci2-l,2,3,4,6-PeCDF;4ng >’Ci2-l,2,3,4,6,9-HxCDFL4ng >’Ci2-l,2,3,4,6,8,9-HpCDF:4ng ’ Field duplicates may not be consistently collected at a frequency of 1/week during ..^tetsment and Demolitio.n Phases as the location selected for analysis will be dictated by PMiomeasurements. ’ Will he collected at a frequency of 1 /day; during .'sbatemeni am Oemolition Phases only 1 field/trip blank per week will be analyzed. Reanalyze: refers to reanalysis of the same extract.

Tab/e 8-6, Measurement Performance Criteria Tab/e-Mercurv Ar QC Sample or Frequency Measurement Corrective DQI Activity Performance Action Criteria Field 1/eveiy other week *RPD < 40 Assess Precision- Duplicates^ when positive laboratory Overall results for both precision; and samples are > /or qualify 5x QL data. *No situation where one result is detected at > 5x QL and other result is not detected Laboratory 1/prep batch Percent Determine Accuracy/Bias Control recoveries 80- cause of Sample 120% problem, reanalyze, and/or qualify data.

46

CITY_DEP_WORBY_CANNATA_SUBP_000058423

NYC-WTC_000423415

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000423415Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000424189

Plan title and approval sheet for environmental air monitoring, Greenwich/Thames.

Similar indexed content

NYC-WTC_000427582

CoC document for Greenwich/Thames Street air monitoring plan dated Nov 9, 2005.

Similar indexed content

NYC-WTC_000426214

Plan document outlining community air monitoring for Greenwich and Thames sites.

Similar indexed content

NYC-WTC_000426688

Plan document for environmental community air monitoring at Greenwich/Thames sites, Sept 2005.

Similar indexed content

NYC-WTC_000425068

Title and approval sheet for Environmental Community Air Monitoring Program and plan at Greenwich and Thames sites.

Similar indexed content

Compare copies and versions →